Belden Store
Belden86406CY

Product Number: 86406CY

XTRAGUARD FLEX, 6PR #28, Str, PVC, Semi Rigid, 300 V, AWM/STYLE 10002 105C, AWM/STYLE 2661 105C, CM 105C, SUN RES, CSA AWM I/II A/B, CSA C(UL) TYPE CMG, CSA FT4

XTRAGUARD FLEX, 6 Pair 28 AWG (7/36) TC - Tinned Copper, PVC, Semi Rigid Insulation, Overall Aluminum/Polyester Shield, Slate PVC Outer Jacket, AWM/STYLE 10002 105C, AWM/STYLE 2661 105C, CM 105C, SUN RES, CSA AWM I/II A/B, CSA C(UL) TYPE CMG, CSA FT4 AWM I/II A/B, C(UL) TYPE CMG, FT4 UL FT4; CSA FT4

Availability
Global
Status
Active
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

86406CY is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthOrder
86406CY SL005SlateReel100 ftOrder online
86406CY SL002SlateReel500 ftOrder online

Specifications

Product Overview

Suitable ApplicationsData, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Construction Details

Overall Cable Diameter (Nominal)0.293 in (7.44 mm)

Conductor

ElementPair(s)
No. of Elements6
Size28 AWG
Stranding7x36
MaterialTC - Tinned Copper

Insulation

ElementPair(s)
MaterialSR-PVC - Polyvinyl Chloride (Semi-Rigid)
Nom. Thickness0.010 in (0.25 mm)
Nom. Insulation Diameter0.035 in (0.89 mm)
Color CodeBlack-Red, Black-White, Black-Green, Black-Blue, Black-Brown, Black-Yellow

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeBi-Laminate (Alum+Poly)100%26 AWG (7x34) TC
BraidTinned Copper (TC)85%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.040 in (1.0 mm)
Nom. Diameter0.293 in (7.44 mm)

Electrical Characteristics

Nom Outer Shield DCR34 Ohm/1000ft (110 Ohm/km)

Electricals

ElementPair(s)
Nom. Capacitance Cond-to-Cond19.1 pF/ft (62.7 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)34 pF/ft (110 pF/m)
Nom. Characteristic Impedence97 Ohm
Nom. Inductance0.22 μH/ft (0.72 μH/m)

Voltage

UL Voltage Rating300 V (AWM 2661, CMG, CM)
Voltage Rating300 V (CSA AWM)

Mechanical Characteristics

Max. Pull Tension97 lbs (44 kg)

Temperature

UL Temperature105°C
Operating-10°C To +105°C
Installation+5°C To +105°C

Bend Radius

Stationary Min.2.9 in (74 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance
SustainabilityCA Prop 65
Flammability / Reaction to FireUL1685 FT4 Loading, FT4
NEC / UL ComplianceArticle 800, CMG, CM
AWM ComplianceAWM 2661, AWM I/II A/B
CEC / C(UL) ComplianceCMG.
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesAlpha Wire -* P/N 86406CY 6PR 28 AWG XTRAGUARD(R) CONTINUOUS FLEX DATA CABLE (UL) 105C TYPE CM SUN RES OR C(UL) CMG OR AWM 2661 105C 300V --- LLXXXXXX CSA AWM I/II A/B FT4 105C 300V CE ROHS OIL RESISTANT (SEQ FOOTAGE)

History

Update and RevisionRevision Number: 0.9 Revision Date: 06-30-2026

Resources

Related flex cable