Belden Store
7453W

Product Number: 7453W

MachFlexTM, 3+1 C #6 Str BC, PVC-NYL Ins, TPE Jkt, 1000V WTTC, 600V TC-ER

MachFlexTM for High Flex, 3+1 Conductor 6AWG (259(7x37)x30) Bare Copper, PVC-NYL Insulation, TPE Outer Jacket, 1000V WTTC, 600V TC-ER

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

7453W is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCFootnoteOrder
7453W 060250ChromeReel250 ft612825187035COrder online

Specifications

Product Overview

Suitable ApplicationsRobotics, Robot, Continuous Flex

Construction Details

Overall Cable Diameter (Nominal)0.875 in

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)36 AWG259x30BC - Bare Copper
Ground Wire16 AWG259x30BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)PVC/Nylon - Polyvinyl Chloride + Nylon0.033 in (0.84 mm)0.276 in (7.01 mm)Black and Numbered
Ground WirePVC/Nylon - Polyvinyl Chloride + Nylon0.033 in (0.84 mm)0.276 in (7.01 mm)Green/Yellow

Outer Shield

MaterialNo Shield

Outer Jacket

Separatornon-Woven Tape
MaterialTPE - Thermoplastic Elastomer
Nom. Thickness0.085 in (2.2 mm)
Nom. Diameter0.875 in

Electrical Characteristics

Electricals

ElementNom. Conductor DCRMax. Current
Conductor(s)0.41 Ohm/1000ft62 Amps per Conductor at 25oC
Ground Wire0.41 Ohm/1000ft (1.3 Ohm/km)62 Amps per Conductor at 25oC

Voltage

UL Voltage Rating1000 V (WTTC), 600 V (TC-ER)

Mechanical Characteristics

Max. Pull Tension1346.8 lbs (610.90 kg)
Bulk Cable Weight591 lbs/1000ft

Temperature

UL TemperatureTC-ER: 90°C Dry, 75°C Wet; AWM 20328: 105°C; AWM I/II A/B: 105°C
Operating-40°C To +105°C

Bend Radius

Stationary Min.3.5 in (89 mm)
Installation Min.4.37 in

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Oil Resistance
Flammability / Reaction to FireUL1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336
AWM ComplianceAWM 20328, AWM I/II A/B
CEC / C(UL) ComplianceCIC, TC.
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.260 Revision Date: 09-07-2025
FootnoteC - CRATE REEL PUT-UP.

Resources

Related flex cable