MachFlexTM, 3+1 C #8 Str BC, PVC-NYL Ins, OA TC Brd, TPE Jkt, TPE Jkt, 1000V WTTC, 600V TC-ER
MachFlexTM for High Flex, 3+1 Conductor 8AWG (168(7x24)x30) Bare Copper, PVC-NYL Insulation, Overall Tinned Copper Braid(85%) Shield, TPE Inner Jacket, TPE Outer Jacket, 1000V WTTC, 600V TC-ER
- Availability
- Global
- Status
- Active
- Orderable items
- 2
Part numbers
7450WS is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Putup Type | Length | UPC | Footnote | Order |
|---|---|---|---|---|---|---|
| 7450WS 060250 | Chrome | Reel | 250 ft | 612825186991 | C | Order online |
| 7450WS 0601000 | Chrome | Reel | 1,000 ft | 612825186984 | C | Order online |
Specifications
Product Overview
| Suitable Applications | Robotics, Robot, Continuous Flex |
|---|
Construction Details
| Overall Cable Diameter (Nominal) | 0.876 in (22.3 mm) |
|---|
Conductor
| Element | No. of Elements | Size | Stranding | Material |
|---|---|---|---|---|
| Conductor(s) | 3 | 8 AWG | 168x30 | BC - Bare Copper |
| Ground Wire | 1 | 8 AWG | 168x30 | BC - Bare Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|---|
| Conductor(s) | PVC/Nylon - Polyvinyl Chloride + Nylon | 0.037 in (0.94 mm) | 0.247 in (6.27 mm) | Black and Numbered |
| Ground Wire | PVC/Nylon - Polyvinyl Chloride + Nylon | 0.037 in (0.94 mm) | 0.247 in (6.27 mm) | Green/Yellow |
Outer Shield
| Shield Type | Braid |
|---|---|
| Material | Tinned Copper (TC) |
| Coverage | 85% |
Inner Jacket
| Separator | non-Woven Tape |
|---|---|
| Material | TPE - Thermoplastic Elastomer |
| Nom. Thickness | 0.040 in (1.0 mm) |
| Nom. Diameter | 0.712 in (18.1 mm) |
| Color | Chrome |
Outer Jacket
| Material | TPE - Thermoplastic Elastomer |
|---|---|
| Nom. Thickness | 0.085 in (2.2 mm) |
| Nom. Diameter | 0.87 in (22 mm) |
Electrical Characteristics
| Nom Outer Shield DCR | 2.04 Ohm/1000ft (6.69 Ohm/km) |
|---|
Electricals
| Element | Nom. Conductor DCR | Max. Current |
|---|---|---|
| Conductor(s) | 1 Ohm/1000ft (3.3 Ohm/km) | 55 Amps per Conductor at 30oC |
| Ground Wire | 1.08 Ohm/1000ft (3.54 Ohm/km) |
Voltage
| UL Voltage Rating | 1000 V (WTTC), 600 V (TC-ER) |
|---|
Mechanical Characteristics
| Max. Pull Tension | 1017 lbs (461.3 kg) |
|---|---|
| Bulk Cable Weight | 526 lbs/1000ft (783 kg/km) |
Temperature
| UL Temperature | UL : 90°C Dry, 75°C Wet; AWM 20328 : 105°C |
|---|---|
| Operating | -40°C To +105°C |
Bend Radius
| Stationary Min. | 6 in (150 mm) |
|---|---|
| Installation Min. | 9 in (230 mm) |
| Flexing Min. | 11 in |
Standards and Compliance
| Environmental Suitability | Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance |
|---|---|
| Flammability / Reaction to Fire | UL1685 UL Loading, IEEE 1202 FT4 |
| NEC / UL Compliance | Article 336, TC-ER, WTTC |
| AWM Compliance | AWM 20328, AWM I/II A/B |
| CEC / C(UL) Compliance | CIC, TC. |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
History
| Update and Revision | Revision Number: 0.608 Revision Date: 07-02-2026 |
|---|---|
| Footnote | C - CRATE REEL PUT-UP. |
Resources
Related flex cable

10C0.14HH
MachFlexTM LiHH, 10 C 0.14mm2 Str BC, PE Ins, LSZH Jkt
10 · 0.14 mm2 · BC - Bare Copper · PE - Polyethylene

10C0.14YCY
MachFlexTM LiYCY, 10 C 0.14mm2 Str BC, PVC Ins, TCBS, PVC Jkt
10 · 0.14 mm2 · BC - Bare Copper · PVC - Polyvinyl Chloride

10C0.14YY
MachFlexTM LiYY, 10 C 0.14mm2 Str BC, PVC Ins, PVC Jkt
10 · 0.14 mm2 · BC - Bare Copper · PVC - Polyvinyl Chloride

10C0.25HCH
MachFlexTM LiHCH, 10 C 0.25mm2 Str BC, PE Ins, TCBS, LSZH Jkt
10 · 0.25 mm2 · BC - Bare Copper · PE - Polyethylene