Belden Store
7438WS

Product Number: 7438WS

MachFlexTM, 6+1G C #14 Str BC, PVC-NYL Ins, OA TC Brd, TPE Jkt, TPE Jkt, 1000V WTTC, 600V TC-ER

MachFlexTM for High Flex, 6+1G Conductor 14AWG (41x30) Bare Copper, PVC-NYL Insulation, Overall Tinned Copper Braid(85%) Shield, TPE Inner Jacket, TPE Outer Jacket, 1000V WTTC, 600V TC-ER

Availability
Global
Status
Active
Orderable items
3

Ships from and sold by A5 IT.

Part numbers

7438WS is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCFootnoteOrder
7438WS 060250ChromeReel250 ft612825186694COrder online
7438WS 0601000ChromeReel1,000 ft612825186687COrder online
7438WS 0605000ChromeReel5,000 ft612825186700—Order online

Specifications

Product Overview

Suitable ApplicationsRobotics, Robot, Continuous Flex

Construction Details

Overall Cable Diameter (Nominal)0.598 in

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)614 AWG41x30BC - Bare Copper
Ground Wire114 AWG41x30BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)PVC/Nylon - Polyvinyl Chloride + Nylon0.021 in (0.53 mm)0.117 in (2.97 mm)Black and Numbered
Ground WirePVC/Nylon - Polyvinyl Chloride + Nylon0.021 in (0.53 mm)0.117 in (2.97 mm)Green/Yellow

Outer Shield

Shield TypeBraid
MaterialTinned Copper (TC)
Coverage85%

Inner Jacket

Separatornon-Woven Tape
MaterialTPE - Thermoplastic Elastomer
Nom. Thickness0.25 in (6.4 mm)
Nom. Diameter0.444 in (11.3 mm)
ColorChrome

Outer Jacket

MaterialTPE - Thermoplastic Elastomer
Nom. Thickness0.063 in (1.6 mm)
Nom. Diameter0.598 in

Electrical Characteristics

Nom Outer Shield DCR3.1 Ohm/1000ft (10 Ohm/km)

Electricals

ElementNom. Conductor DCRMax. Current
Conductor(s)2.8 Ohm/1000ft21 Amps per Conductor at 25oC
Ground Wire2.73 Ohm/1000ft (8.96 Ohm/km)

Voltage

UL Voltage Rating1000 V (WTTC), 600 V (TC-ER)

Mechanical Characteristics

Max. Pull Tension469 lbs (213 kg)
Bulk Cable Weight236 lbs/1000ft

Temperature

UL TemperatureUL : 90°C Dry, 75°C Wet; AWM 20328 : 105°C
Operating-40°C To +105°C

Bend Radius

Stationary Min.7.18 in (182 mm)
Installation Min.7.18 in

Standards and Compliance

Environmental SuitabilityOutdoor, Sunlight Resistance, UV Resistance, Oil Resistance
Flammability / Reaction to FireUL1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336
AWM ComplianceAWM 20328, AWM I/II A/B
CEC / C(UL) ComplianceCIC, TC.
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.369 Revision Date: 09-07-2025
FootnoteC - CRATE REEL PUT-UP.