Belden Store
7423WS

Product Number: 7423WS

MachFlexTM, 3+1G C #16 Str BC, PVC-NYL Ins, OA TC Brd, TPE Jkt, TPE Jkt, 1000V WTTC, 600V TC-ER

MachFlexTM for High Flex, 3+1G Conductor 16AWG (26x30) Bare Copper, PVC-NYL Insulation, Overall Tinned Copper Braid(85%) Shield, TPE Inner Jacket, TPE Outer Jacket, 1000V WTTC, 600V TC-ER

Availability
Global
Status
Active
Orderable items
3

Ships from and sold by A5 IT.

Part numbers

7423WS is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCFootnoteOrder
7423WS 060250ChromeReel250 ft612825186250COrder online
7423WS 0601000ChromeReel1,000 ft612825186243COrder online
7423WS 0605000ChromeReel5,000 ft612825186267—Order online

Specifications

Product Overview

Suitable ApplicationsRobotics, Robot, Continuous Flex

Construction Details

Overall Cable Diameter (Nominal)0.42 in

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)316 AWG26x30BC - Bare Copper
Ground Wire116 AWG26x30BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)PVC/Nylon - Polyvinyl Chloride + Nylon0.021 in (0.53 mm)0.101 in (2.57 mm)Black and Numbered
Ground WirePVC/Nylon - Polyvinyl Chloride + Nylon0.021 in (0.53 mm)0.101 in (2.57 mm)Green/Yellow

Outer Shield

Shield TypeBraid
MaterialTinned Copper (TC)
Coverage85%

Inner Jacket

Separatornon-Woven Tape
MaterialTPE - Thermoplastic Elastomer
Nom. Thickness0.25 in (6.4 mm)
Nom. Diameter0.298 in (7.57 mm)
ColorChrome

Outer Jacket

MaterialTPE - Thermoplastic Elastomer
Nom. Thickness0.047 in (1.2 mm)
Nom. Diameter0.42 in

Electrical Characteristics

Nom Outer Shield DCR3.21 Ohm/1000ft (10.5 Ohm/km)

Electricals

ElementNom. Conductor DCRMax. Current
Conductor(s)4.18 Ohm/1000ft19 Amps per Conductor at 30oC
Ground Wire4.45 Ohm/1000ft (14.6 Ohm/km)30.4 Amps per Conductor at 30oC

Voltage

UL Voltage Rating1000 V (WTTC), 600 V (TC-ER)

Mechanical Characteristics

Max. Pull Tension160 lbs (73 kg)
Bulk Cable Weight122 lbs/1000ft

Temperature

UL TemperatureUL : 90°C Dry, 75°C Wet; AWM 20328 : 105°C
Operating-40°C To 105°C

Bend Radius

Stationary Min.1.68 in (42.7 mm)
Installation Min.2.1 in

Standards and Compliance

Environmental SuitabilityOutdoor, Sunlight Resistance, UV Resistance, Oil Resistance
Flammability / Reaction to FireUL1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336
AWM ComplianceAWM 20328, AWM I/II A/B
CEC / C(UL) ComplianceCIC, TC.
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.250 Revision Date: 09-07-2025
FootnoteC - CRATE REEL PUT-UP.

Resources