VFD 100% Gnd, 3C #1/0 Str TC XLPE Ins + #1/0 Symm. Seg. Gnd (3 of #4) Str TC, CTS, Blk TPE Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC
Belden 100% Ground Extra Flexible VFD, 3 Conductor 1/0AWG (19x56x30) Tinned Copper XLPE Insulation M4 Color Code + 1/0AWG Symmetrical Segmented Ground (3 of 4AWG) Tinned Copper Stranded, Overall Dual Copper Tape Helically Applied Shield, Black TPE Outer Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable 1000V WTTC 600V CIC TC SUN RES OIL RES II
- Availability
- Global
- Status
- Active
- Orderable items
- 1
Part numbers
29529F is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Putup Type | UPC | Order |
|---|---|---|---|---|
| 29529F 0102500 | Black | Reel | 612825373391 | Order online |
Specifications
Product Overview
| Suitable Applications | Variable Frequency Drives (VFD); AC Motor and Drive Systems, Exposure to high flex, motion, and abrasion, Hard to reach installation areas; Class 1 Division 2 Hazardous Locations |
|---|
Construction Details
| Overall Cable Diameter (Nominal) | 1.292 in (32.82 mm) |
|---|
Conductor
| Element | No. of Elements | Size | Stranding | Material | Notes |
|---|---|---|---|---|---|
| Conductor(s) | 3 | 1/0 AWG | 19x56x30 | TC - Tinned Copper | |
| Ground | 3 | 4 AWG | 7x60x30 | TC - Tinned Copper | Segmented Grounds |
Insulation
| Element | Material | Nom. Thickness | Color Code |
|---|---|---|---|
| Conductor(s) | XLPE - Cross-Linked Polyethylene (Thermoset) | 0.057 in (1.4 mm) | Black and Numbered |
| Ground | No Insulation |
Outer Shield
| Shield Type | Material | Coverage |
|---|---|---|
| Helical Tape | Bare Copper (BC) | 100% |
| Helical Tape | Bare Copper (BC) | 100% |
Outer Jacket
| Material | TPE - Thermoplastic Elastomer |
|---|---|
| Nom. Thickness | 0.083 in (2.1 mm) |
| Nom. Diameter | 1.292 in (32.82 mm) |
| Ripcord | Yes |
Electrical Characteristics
Electricals
| Element | Conductor(s) |
|---|---|
| Nom. Conductor DCR | 0.096 Ohm/1000ft (0.31 Ohm/km) |
| Nom. Capacitance Cond-to-Cond | 23 pF/ft (75 pF/m) |
| Nom. Capacitance Cond-to-Other (Conds + Shield) | 42 pF/ft (140 pF/m) |
| Nom. Characteristic Impedence | 80 Ohm |
| Nom. Velocity of Prop. | 55% |
| Max. Current | 170 Amps per Conductor at 30oC (per NEC) |
Voltage
| UL Voltage Rating | 1000 V (TC, WTTC, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) |
|---|
Mechanical Characteristics
| Max. Pull Tension | 5787 lbs (2625 kg) |
|---|---|
| Bulk Cable Weight | 1763 lbs/1000ft (2624 kg/km) |
Temperature
| UL Temperature | 90°C Dry, 90°C Wet |
|---|---|
| Operating | -40°C To +90°C |
Bend Radius
| Stationary Min. | 7.5 in (190 mm) |
|---|---|
| Installation Min. | 15.5 in (394 mm) |
| Flexing Min. | 15.5 in (394 mm) |
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial |
|---|---|
| Sustainability | CA Prop 65 |
| Flammability / Reaction to Fire | UL1685 UL Loading, FT4, 1202, 383 Vertical Tray Flame Test (70,000 BTU) |
| NEC / UL Compliance | Article 336, TC-ER, WTTC, XHHW-2, UL Flexible Motor Supply Cable |
| CEC / C(UL) Compliance | CIC, TC. |
| ICEA Compliance | S-95-658 |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
History
| Update and Revision | Revision Number: 0.596 Revision Date: 03-24-2026 |
|---|
Resources
Related flex cable

10C0.14HH
MachFlexTM LiHH, 10 C 0.14mm2 Str BC, PE Ins, LSZH Jkt
10 · 0.14 mm2 · BC - Bare Copper · PE - Polyethylene

10C0.14YCY
MachFlexTM LiYCY, 10 C 0.14mm2 Str BC, PVC Ins, TCBS, PVC Jkt
10 · 0.14 mm2 · BC - Bare Copper · PVC - Polyvinyl Chloride

10C0.14YY
MachFlexTM LiYY, 10 C 0.14mm2 Str BC, PVC Ins, PVC Jkt
10 · 0.14 mm2 · BC - Bare Copper · PVC - Polyvinyl Chloride

10C0.25HCH
MachFlexTM LiHCH, 10 C 0.25mm2 Str BC, PE Ins, TCBS, LSZH Jkt
10 · 0.25 mm2 · BC - Bare Copper · PE - Polyethylene