Belden Store
29501F

Product Number: 29501F

VFD 300% Gnd, 3C+G #14 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd w/#14 TC Drain, Blk TPE Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC

Belden 300% Ground Extra Flexible VFD, 3 Conductor 14AWG (104x30) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil®+Tinned Copper Braid(85%) Shield w/14AWG Tinned Copper Drain, Black TPE Outer Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable 1000V WTTC 600V CIC TC SUN RES OIL RES II

Availability
Global
Status
Active
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

29501F is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCOrder
29501F 0101000BlackReel1,000 ft612825367222Order online
29501F 0105000BlackReel5,000 ft612825367253Order online

Specifications

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems, Exposure to high flex, motion, and abrasion, Hard to reach installation areas

Construction Details

Overall Cable Diameter (Nominal)0.587 in (14.9 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)314 AWG104x34TC - Tinned Copper
Ground Wire114 AWG104x34TC - Tinned Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPO - Crosslink Polyolefin0.046 in (1.2 mm)0.167 in (4.24 mm)ICEA Chart M4
Ground WirePVC - Polyvinyl Chloride0.046 in (1.2 mm)0.167 in (4.24 mm)Green/Yellow Stripe

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeTri-Laminate (Alum+Poly+Alum)100%14 AWG (104x34) TC
BraidTinned Copper (TC)85%

Outer Jacket

SeparatorPolyester Tape
MaterialTPE - Thermoplastic Elastomer
Nom. Thickness0.073 in (1.9 mm)
Nom. Diameter0.587 in (14.9 mm)
RipcordYes

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)2.468 Ohm/1000ft (8.097 Ohm/km)40 pF/ft (130 pF/m)72 pF/ft (240 pF/m)46 Ohm55%25 Amps per Conductor at 30oC (per NEC)
2.73 Ohm/1000ft (8.96 Ohm/km)

Voltage

UL Voltage Rating1000 V (TC-ER, XHHW-2, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC)

Mechanical Characteristics

Max. Pull Tension340 lbs (150 kg)
Bulk Cable Weight216 lbs/1000ft (321 kg/km)

Temperature

UL Temperature90°C Dry, 90°C Wet
Operating-40°C To +90°C

Bend Radius

Stationary Min.7.0 in (180 mm)
Installation Min.7.0 in (180 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, FT4, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, Article 310, TC-ER, XHHW-2, UL Flexible Motor Supply Cable
CEC / C(UL) ComplianceCIC, TC.
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.235 Revision Date: 03-19-2026