Belden Store
10C0.34HCH

Product Number: 10C0.34HCH

MachFlexTM LiHCH, 10 C 0.34mm2 Str BC, PE Ins, TCBS, LSZH Jkt

MachFlexTM LiHCH LSZH Control & Signal Cables, 10 Conductor 0.34mm2 Stranded Bare Copper, Polyethylene Insulation, Tinned Copper Braid Shield, LSZH Jacket

Availability
EMEA | Asia Pacific
Status
Active
Orderable items
9

Ships from and sold by A5 IT.

Part numbers

10C0.34HCH is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorLengthOrder
10C0.34HCH 010100MBlack100 mOrder online
10C0.34HCH 010200MBlack200 mOrder online
10C0.34HCH 010300MBlack300 mOrder online
10C0.34HCH 006100MBlue100 mOrder online
10C0.34HCH 006200MBlue200 mOrder online
10C0.34HCH 006300MBlue300 mOrder online
10C0.34HCH F2V100MGray, RAL 7032100 mOrder online
10C0.34HCH F2V200MGray, RAL 7032200 mOrder online
10C0.34HCH F2V300MGray, RAL 7032300 mOrder online

Specifications

Product Overview

Suitable ApplicationsDesigned for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, pressure gauge, temperature controllers, control panels, vibration monitoring systems, intelligent security controllers, production machinery and many more. Tinned cooper braid shield ensure the cables with excellent noise immunity. This LSZH version with UL certification emits limited smoke and no halogen when exposed to high sources of heat. It can considerably reduce the amount and density of the smoke, toxic and corrosive gas emitted during a fire, enable easier evacuation as well as safer firefighting operations.

Construction Details

Overall Cable Diameter (Nominal)6.5 mm (0.26 in)

Conductor

ElementConductor(s)
No. of Elements10
Size0.34 mm2
StrandingStranded
MaterialBC - Bare Copper

Insulation

MaterialPE - Polyethylene
Color CodeWhite, Brown, Green, Yellow, Gray, Pink, Blue, Red, Black, Violet

Outer Shield

Shield TypeBraid
MaterialTinned Copper (TC)

Outer Jacket

MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)

Electrical Characteristics

Electricals

Nom. Capacitance Cond-to-Cond80 pF/m (24 pF/ft)
Nom. Capacitance Cond-to-Shield120 pF/m (37 pF/ft)

Voltage

Voltage Rating500 V (Max. Operating Voltage), 1500 V (Testing Voltage)

Mechanical Characteristics

Bulk Cable Weight65 kg/km (44 lbs/1000ft)

Temperature

Operating‐5°C to +70°C(Occasional movement)
Installation‐40°C to +80°C(Fixed installation)

Bend Radius

Installation Min.39 mm (1.5 in)
Flexing Min.97.5 mm

Standards and Compliance

Environmental SuitabilitySunlight Resistance, UV Resistance
Flammability / Reaction to FireIEC 60332-1-2, DIN VDE 0482-332-1-2, DIN EN 60332-1-2
ISO/IEC ComplianceIEC 60228
CENELEC ComplianceEN 50290-2-22, EN 50363-4-1
European Halogen Free StandardsIEC 60754-1 - Halogen Amount = IEC 60754-1, IEC 60754-2
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2)
Other Standard Compliance(s)EN 61034-2, VDE 0812, DIN 47100, BS 6360

Product Notes

NotesSmoke/Halogen Properties : IEC 60754-1, IEC 60754-2, VDE 0482-754-1, VDE 0482-754-2

History

Update and RevisionRevision Number: 0.31 Revision Date: 01-15-2026

Resources