2C1.5mm2, Cu. Cond., PVC Ins, TPE Jkt As-Interface Bus Flat Cable
2 Cores 1.5 mm2, Stranded Annealed Tinned Copper Conductors, PVC insulated & Overall TPE Jacket As- Interface Bus Flat cable.
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Suitable Applications | For appliactions upto and inculding 300V. |
|---|
Construction Details
| Conductor Spacing Center-Center | 3.6 ± 0.2 mm |
|---|
Conductor
| Element | Conductor(s) |
|---|---|
| No. of Elements | 2 |
| Size | 1.5 mm2 |
| Material | TC - Tinned Copper (High Conductivity) |
Insulation
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Thickness | 0.5 mm (0.020 in) |
| Nom. Insulation Diameter | 2.5 mm (0.098 in) |
| Color Code | Brown, Blue |
Outer Jacket
| Material | Nom. Thickness | Nom. Thickness Flat Section | Nom. Width |
|---|---|---|---|
| TPE - Thermoplastic Elastomer | 0.55 mm (0.022 in) | 6.5 mm (0.26 in) | |
| 4.0 mm (0.16 in) | 10 mm (0.39 in) |
Electrical Characteristics
Electricals
| Max. Conductor DCR | 13.7 Ohms @ 20 Deg C |
|---|---|
| Nom. Capacitance Cond-to-Cond | 80 pF/ft (260 pF/m) |
Voltage
| UL Voltage Rating | 300 V |
|---|---|
| Breakdown Voltage | 2000 V |
Mechanical Characteristics
Temperature
| Operating | -30°C to +105°C |
|---|
Standards and Compliance
| Flammability / Reaction to Fire | FT4 |
|---|---|
| AWM Compliance | AWM I/II A/B |
| CEC / C(UL) Compliance | C22.2 No.210.2. |
| European Directive Compliance | EU Directive 2011/65/EU (RoHS 2) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Other Standard Compliance(s) | UL 758 |
Product Notes
| Notes | UL 13, EN 50295, IEC 62026-2 |
|---|
History
| Update and Revision | Revision Number: 0.11 Revision Date: 05-31-2024 |
|---|