Belden Store
Belden6454

Product Number: 6454

IA, 1C #22, Str, Foam HDPE, 300 V, PLTC 60C, CM 60C, SUN RES, CSA CM, CSA FT1

IA, 1 Conductor 22 AWG (7/.0096) TC - Tinned Copper, Foam HDPE Insulation, Overall Tinned Copper Shield, Black PVC Outer Jacket, PLTC 60C, CM 60C, SUN RES, CSA CM, CSA FT1 cm, FT1 UL FT1; CSA FT1

Availability
Global
Status
Active
Orderable items
3

Ships from and sold by A5 IT.

Part numbers

6454 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthOrder
6454 BK005BlackReel100 ftOrder online
6454 BK002BlackReel500 ftOrder online
6454 BK001BlackReel1,000 ftOrder online

Specifications

Product Overview

Suitable ApplicationsData, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Construction Details

Overall Cable Diameter (Nominal)0.300 in (7.62 mm)

Conductor

ElementComm
No. of Elements1
Size22 AWG
Stranding7x31
MaterialTC - Tinned Copper

Insulation

ElementComm
MaterialHDPE - High-Density Polyethylene
Nom. Thickness0.033 in (0.84 mm)
Nom. Insulation Diameter0.095 in (2.4 mm)
Color CodeBlue/White

Inner Shield

ElementComm
Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type22 AWG (7x30) TC

Outer Shield

Shield TypeBraid
MaterialTinned Copper (TC)
Coverage65%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.042 in (1.1 mm)
Nom. Diameter0.300 in (7.62 mm)

Electrical Characteristics

Nom Outer Shield DCR52 Ohm/1000ft (170 Ohm/km)

Electricals

ElementComm
Nom. Capacitance Cond-to-Cond11 pF/ft (36 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)209 pF/ft (686 pF/m)
Nom. Characteristic Impedence120 Ohm
Max. Current2.7 A

Voltage

UL Voltage Rating300 V (CM, PLTC)

Mechanical Characteristics

Max. Pull Tension143 lbs (64.9 kg)

Temperature

UL Temperature60°C
Operating-20°C To +60°C

Bend Radius

Stationary Min.3.0 in (76 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Sunlight Resistance
Flammability / Reaction to FireUL1685 FT1 Loading, FT1
NEC / UL ComplianceArticle 725, Article 800, CM, PLTC
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesALPHA WIRE P/N 6454 E34972-48 3C22 SHIELDED (UL) CM OR PLTC SUN RES OR C(UL) CM --- FT1 CE ROHS

History

Update and RevisionRevision Number: 0.112 Revision Date: 06-30-2026

Resources

Related devicenet cable