Universal OFC MLT: ARAMID + LSZH + SWA + LSZH (HIGH TEMP) with 12 gel-free tubes of Ø1.9mm 120f SM OS2 G.657.B3. CPR Eca.

Universal (Indoor/Outdoor) dry core optical fiber Multi Loose Tube cable with aramid yarns as strength member, Low Smoke Zero Halogen inner jacket, Steel Wire Armouring (Full Rodent Protected) armor and Low Smoke Zero Halogen outer jacket. Product feature: This cable has improved rodent protection by Steel Wire Armouring (Full Rodent Protected). Existing out of 12 gel-free tubes with a diameter of 1.9mm with 120 fibers (10t x 12f) SM OS2 G.657.B3. CPR Euroclass Eca.

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Product Overview

Environmental SpaceIndoor/Outdoor - Euroclass Eca
Suitable ApplicationsFor outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor and indoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches and/or tubes. Suitable for Direct Burial.

Construction

Fiber Color CodeTIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua
Central Strength Member TypeGRP
Cable Core Water TightYes
Cable Core Water BlockingWaterblocking Aramid Yarns + Tape
Bulk Cable Weight528 kg/km

Fiber Cable Construction

Fiber TypeOS2
Fiber Grade acc. ITU-TG.657B3
Fiber Count120
Subunit ColorTIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet

SubUnit Specifications

Number of Active Subunits10
Number of Subunit Positions12
Fibers Per Subunit12

Physical Specifications

Type of ArmorSteel Wire

Jacket Specifications

Number of JacketsDouble Jacket

Inner Jacket

MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)

Outer Jacket Specifications

Outer Jacket1 Table NotesStandard color: Black. Available colors: Black, Orange, Yellow, Turquoise, Erika Violet, Red, Blue, Green, Brown, Violet, Pink, Grey, White, Lime Green

Outer Jacket

MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Nominal Diameter18.1 mm
RipcordYes

Optical Characteristics

Maximum Attenuation at 1310 nm0.40 dB/km
Maximum Attenuation at 1550 nm0.30 dB/km
Maximum Attenuation at 1625 nm0.30 dB/km

Mechanical Characteristics

Mechanical Tests

DescriptionTested StandardRequirement/ValueAccording to Family Specification
Cable Min. Bend Radius Installation (Short Term)IEC 60794-1-21-E6362 mmIEC 60794-3-10
Cable Min. Bend Radius Operation (Long Term)IEC 60794-1-21-E11362 mmIEC 60794-3-10
Cable Max. Tensile Strength Installation (Short Term)IEC 60794-1-21-E12850 N (641 lbf)IEC 60794-3-10
Cable Max. Tensile Strength Operation (Long Term)IEC 60794-1-21-E1950 N (214 lbf)IEC 60794-3-10
Cable Max. Crush Resistance Installation (Short Term)IEC 60794-1-21-E322 kN/mIEC 60794-3-10
Cable Max. Crush Resistance Operation (Long Term)IEC 60794-1-21-E311 kN/mIEC 60794-3-10
Cable Impact ResistanceIEC 60794-1-21-E410 J, 300 mm Radius, 3 CyclesIEC 60794-3-10
Cable Torsion ResistanceIEC 60794-1-21-E7180°, 2 m, 10 cyclesIEC 60794-3-10
WaterblockingIEC 60794-1-22-F5

Temperature Range

Operating Temperature Range-30 °C to +70 °C
Installation Temperature Range-5 °C to +50 °C
Storage Temperature Range-30 °C to +70 °C

Product Material

UL Rating/Flame TestNon-UL Rated

Standards

IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity10 μS/mm
IEC FlammabilityIEC 60332-1-2
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH4.3
IEC 60754-1 - Halogen AmountZero
CPR EuroclassEca
REACHCompliant
ISO/IEC ComplianceIEC 60794, ISO/IEC 11801-1
UV/ Sunlight ProtectionYes