OM3, MLT, Dry Core, FRP Armored, double PE & Nylon Jacket OFC
OM3, MLT, Dry Core –Inner HDPE & Nylon Sheath, Flat FRP Armored, Outer HDPE & Nylon Sheath, All Dielectric Optical Fiber Cable, Termite & Rodent Resistant
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Suitable Applications | For outdoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches and/or tubes. Suitable for Direct Burial. |
|---|
Construction
| Fiber Color Code | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua |
|---|---|
| Cable Core Water Blocking | Waterblocking Yarns + Tape |
| Bulk Cable Weight | 164 kg/km |
Fiber Cable Construction
| Fiber Type | OM3 |
|---|---|
| Fiber Count | 6 |
Buffer Specification
| Buffer Material | Buffer Tube Material:Thermoplastic Material (PBT), Buffer Tube Filling Material: Synthetic Thixotropic Gel |
|---|
Inner Jacket
| Material | PE - Polyethylene |
|---|---|
| Inner Jacket2 Material | Nylon |
Outer Jacket Specifications
| Outer Jacket1 Table Notes | Armor Type: Flat Fiber Reinforced Plastic Rod Cable Overall Diameter: 13.5mm |
|---|
Outer Jacket
| Material |
|---|
| PE - Polyethylene |
| Nylon |
Optical Characteristics
| Maximum Attenuation at 1300 nm | 1.0 dB/km |
|---|---|
| Maximum Attenuation at 850 nm | 3.0 dB/km |
Mechanical Characteristics
Mechanical Tests
| Description | Tested Standard | Requirement/Value |
|---|---|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E11 | 30 x OD |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 15 x OD |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 4000 N (899 lbf) |
| Cable Max. Tensile Strength Operation (Long Term) | IEC 60794-1-21-E1 | 1200 N (270 lbf) |
Temperature Range
| Operating Temperature Range | - 30°C To + 70°C |
|---|---|
| Installation Temperature Range | - 10°C To + 60°C |
| Storage Temperature Range | - 40°C To + 70°C |
Standards
| ISO/IEC Compliance | ISO/IEC 11801 |
|---|
Product Notes
| Notes | Jacket: Inner HDPE & Nylon sheath(black), Outer HDPE & Nylon sheath (blue), Armor Type and Material: Flat Fiber Reinforced Plastic Rod, Maximum Crush Resistance for Short Term: 4000N/100mm, Duration: 1min, Maximum Crush Resistance for Long Term: 2000N/100mm, Duration: 10min |
|---|
History
| Update and Revision | Revision Number: 0.16 Revision Date: 04-15-2025 |
|---|
Resources
Belden DKAG53MA006BEAA technical datasheetDataTuff MiningGrade Fiber Cables Product BulletinGel-Free Loose Tube Fiber Optic Cables - EMEA (English)Gel-Free Loose Tube Fiber Optic Cables - EMEA (German)Gel-Free Loose Tube Fiber Optic Cables7 Cable Types to Consider for Your EnvironmentFiber Products Selection GuideOutdoor Dry Loose Tube CableAll Dielectric Outdoor Loose Tube Dry CableDataTuff Mining-Grade Loose Tube Cable CPE JacketDataTuff Mining-Grade Loose Tube Cable LSZH JacketArmored Outdoor Loose Tube Gel Filled CableAll Dielectric Outdoor Loose Tube Gel Filled CableArmored Indoor Outdoor Loose Tube Gel Filled CableAll Dielectric Indoor/Outdoor Loose Tube Gel Filled CableEvolution of Fiber: Myth vs. RealityBelden Smart Building SolutionsIndustrial Fiber CatalogBelden Fiber Optic Catalog - AmericasOptical Fiber Cable Reference Guide - IECDataTuff Fiber Optic Renewable Grade Cable
Related multi-loose tube fiber cable

DKAG12MA006BEAA
OS2, MLT, Dry Core, FRP Armored, double PE & Nylon Jacket OFC
PE - Polyethylene

DKAG12MA012BEAA
OS2, MLT, Dry Core, FRP Armored, double PE & Nylon Jacket OFC
PE - Polyethylene

DKAG12MA024BEAA
OS2, MLT, Dry Core, FRP Armored, double PE & Nylon Jacket OFC
PE - Polyethylene

DKAG12MA036BEAA
OS2, MLT, Dry Core, FRP Armored, double PE & Nylon Jacket OFC
PE - Polyethylene