Belden Store
GQWM212

Product Number: GQWM212

Universal OFC CLT (gel-free tube): GLASS YARNS + LSZH + SWA + LSZH (HIGH TEMP) with 1 gel-free Tube of Ø3.3mm 12f MM OM2. CPR Eca.

Universal (Indoor/Outdoor) high installation temperature optical fiber Central Loose Tube (gel-free tube) cable with glass yarns as strength member, Low Smoke Zero Halogen inner jacket, Steel Wire Armouring (Full Rodent Protected) armor and Low Smoke Zero Halogen outer jacket. Product feature: This cable has improved rodent protection by Steel Wire Armouring (Full Rodent Protected). Existing out of 1 gel-free Tube with a diameter of 3.3mm with 12 fibers MM OM2. CPR Euroclass Eca.

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Product Overview

Environmental SpaceIndoor/Outdoor
Suitable ApplicationsFor outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor and indoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches and/or tubes. Suitable for Direct Burial.

Construction

Fiber Color CodeTIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua
Cable Core Water TightYes
Cable Core Water BlockingWaterblocking Glass Yarns
Bulk Cable Weight154 kg/km

Fiber Cable Construction

Fiber TypeOM2
Fiber Count12
Subunit ColorTIA coding (Gxxxxxx.T): Natural

SubUnit Specifications

Number of Active Subunits1
Number of Subunit Positions1
Fibers Per Subunit12

Physical Specifications

Type of ArmorSteel Wire

Jacket Specifications

Number of JacketsDouble Jacket

Inner Jacket

Inner Jacket1 Nominal Diameter5.8 mm
MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)

Outer Jacket Specifications

Outer Jacket1 Table NotesStandard color: Orange. Available colors: Orange, Yellow, Turquoise, Erika Violet, Red, Blue, Green, Brown, Violet, Pink, Grey, White, Black, Lime Green

Outer Jacket

MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
ColorBlack
Nominal Diameter10.2 mm
RipcordYes

Optical Characteristics

Maximum Attenuation at 1300 nm0.9 dB/km
Maximum Attenuation at 850 nm2.9 dB/km

Mechanical Characteristics

Mechanical Tests

DescriptionTested StandardRequirement/ValueAccording to Family Specification
Cable Min. Bend Radius Installation (Short Term)IEC 60794-1-21-E6192 mmIEC 60794-3-10
Cable Min. Bend Radius Operation (Long Term)IEC 60794-1-21-E11192 mmIEC 60794-3-10
Cable Max. Tensile Strength Installation (Short Term)IEC 60794-1-21-E11500 N (337 lbf)IEC 60794-3-10
Cable Max. Tensile Strength Operation (Long Term)IEC 60794-1-21-E1500 N (112 lbf)IEC 60794-3-10
Cable Max. Crush Resistance Installation (Short Term)IEC 60794-1-21-E322 kN/mIEC 60794-3-10
Cable Max. Crush Resistance Operation (Long Term)IEC 60794-1-21-E311 kN/mIEC 60794-3-10
WaterblockingIEC 60794-1-22-F5

Temperature Range

Operating Temperature Range-30 °C to +70 °C
Installation Temperature Range-5 °C to +50 °C
Storage Temperature Range-30 °C to +70 °C

Product Material

UL Rating/Flame TestNon-UL Rated

Standards

IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity10 μS/mm
IEC FlammabilityIEC 60332-1-2
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH4.3
IEC 60754-1 - Halogen AmountZero
IEC 61034-2 - Smoke Density Min. Transmittance60%
CPR EuroclassEca
REACHCompliant
ISO/IEC ComplianceIEC 60794, ISO/IEC 11801-1
UV/ Sunlight ProtectionYes

History

Update and RevisionRevision Number: 0.4 Revision Date: 08-21-2025

Resources

Related central loose tube fiber cable