Belden Store
TU-3BB-006-RI2

Product Number: TU-3BB-006-RI2

Tray, In+Outdoor, BO, OM3, 6f, Subunit 2.0mm, AIA, Dbl Jkt, Blk, CPE, OFCR, Oil Res 1/2

Tray Grade, Indoor/Outdoor, Breakout, OM3, 6 Fibers, Subunits 2.0mm 900um, Aluminum Interlock Armor, Double Jacket, Black, CPE, OFCR, Oil Res 1 & 2

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

TU-3BB-006-RI2 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeUPCOrder
TU-3BB-006-RI2NBlackCut to Length612825484943Order online

Specifications

Product Overview

Product CategoryFiber Breakout Cable
Suitable ApplicationsExtended Distance Horizontal & Backbone Data/Telco Network, Noisy Environment, Indoor/Outdoor & Wet Locations, Oil Res 1 /2, Rodent Proof

Fiber Specifications

Fiber TypeOM3
Fiber Core Diameter50/125 μm
Fiber Diameter250 μm
Fiber Buffer MaterialPVC - Polyvinyl Chloride
Fiber Buffer Diameter900 μm
Fiber Count6
Fiber Color CodingTIA-598-D

Cable Construction

Number of Active Subunits6
Fibers Per Subunit1
Subunit Diameter0.078 in (2.0 mm)
Subunit ColorAqua
Fiber SubUnit Strength MembersWaterblocking aramid yarns
Central Strength Member TypeGRP
Core Wrap MaterialWaterblocking tape

Inner Jacket Specifications

Inner Jacket Strength MemberWaterblocking Aramid Yarns
MaterialPVC - Polyvinyl Chloride
Nominal Diameter@InnerJacket1 (cnv)0.382 in (9.7 mm)
ColorBlack
Number of Inner Jacket Ripcords1

Armor Specifications

Armor Type and MaterialAIA - Aluminum Interlock Armor

Outer Jacket Specifications

Jacket MaterialCPE - Chlorinated Polyethylene
Nom. Diameter0.695 in (17.7 mm)

Optical Characteristics

Wavelength850 nm1300 nm
Max. Attenuation3.0 dB/km1.0 dB/km
1 Gigabit Ethernet Performance1,000 m550 m
10 Gigabit Ethernet Performance300 m--
Min. Effective Modal Bandwidth (EMB)2000 MHz.km--
Min. Overfilled Launch (OFL) Bandwidth1500 MHz.km500 MHz.km

Mechanical Characteristics

Minimum Bend Radius During Installation20x Cable OD
Minimum Bend Radius During Operation10x Cable OD
Max. Tensile Strength During Installation1335 N (300 lbf)
Max. Tensile Strength During Operation400 N (90 lbf)
Crush Resistance440 N/cm
Bulk Cable Weight162 lbs/kft (242 kg/km)

Temperature Range

Installation Temperature Range-10°C to +60°C
Operating Temperature Range-50°C to +70°C
Storage Temperature Range-50°C to +70°C

Standards and Compliance

Environmental SuitabilityIndoor/Outdoor, Sunlight Resistance, Oil Resistance, Oil Resistance - Oil Res I/II, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireOFCR, FT4
ICEA ComplianceS-104-696

History

Update and RevisionRevision Number: 0.17 Revision Date: 09-07-2025

Resources