Factory, In+Outdoor, BO, OM3, 4f, Subunit 2.0mm, AIA, Dbl Jkt - PVC, OFCR, Ozone-UV-Oil Res
Factory Grade, Indoor/Outdoor, Breakout, OM3, 4 Fibers, Subunits 2.0mm 900um, Aluminum Interlock Armor, Double Jacket - PVC, OFCR, Ozone-UV-Oil Resistant
- Availability
- Global
- Status
- Active
- Orderable items
- 1
Part numbers
TF-3BB-004-RI5 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Putup Type | Order |
|---|---|---|---|
| TF-3BB-004-RI5N | Black | Reel | Order online |
Specifications
Product Overview
| Product Category | Fiber Breakout Cable |
|---|---|
| Suitable Applications | Extended Distance Horizontal & Backbone Data/Telco Network, Noisy Environment, Indoor/Outdoor & Wet Locations, Rodent Proof |
Fiber Specifications
| Fiber Type | OM3 |
|---|---|
| Fiber Core Diameter | 50 μm |
| Fiber Diameter | 250 μm |
| Fiber Buffer Material | PVC - Polyvinyl Chloride |
| Fiber Buffer Diameter | 900 μm |
| Fiber Count | 4 |
| Fiber Color Coding | TIA-598-D |
Cable Construction
| Number of Active Subunits | 4 |
|---|---|
| Fibers Per Subunit | 1 |
| Subunit Diameter | 0.78 in (2.0 mm) |
| Subunit Color | Aqua |
| Fiber SubUnit Strength Members | Waterblocking aramid yarns |
Inner Jacket Specifications
| Inner Jacket Strength Member | Waterblocking Aramid Yarns |
|---|---|
| Material | PVC - Polyvinyl Chloride |
| Nominal Diameter@InnerJacket1 (cnv) | 0.321 in (8.2 mm) |
| Color | Black |
Armor Specifications
| Armor Type and Material | AIA - Aluminum Interlock Armor |
|---|
Outer Jacket Specifications
| Jacket Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Diameter | 0.635 in (16.1 mm) |
Optical Characteristics
| Wavelength | 850 nm | 1300 nm |
|---|---|---|
| Max. Attenuation | 3.0 dB/km | 1.0 dB/km |
| 1 Gigabit Ethernet Performance | 1000 | 550 |
| 10 Gigabit Ethernet Performance | 300 m | -- |
| Min. Effective Modal Bandwidth (EMB) | 2000 MHz.km | -- |
| Min. Overfilled Launch (OFL) Bandwidth | 1500 MHz.km | 500 MHz.km |
Mechanical Characteristics
| Minimum Bend Radius During Installation | 20x Cable OD |
|---|---|
| Minimum Bend Radius During Operation | 10x Cable OD |
| Max. Tensile Strength During Installation | 1335 N (300 lbf) |
| Max. Tensile Strength During Operation | 400 N (90 lbf) |
| Crush Resistance | 220 N/cm |
| Bulk Cable Weight | 159 lbs/kft (237 kg/km) |
Temperature Range
| Installation Temperature Range | -10°C to +60°C |
|---|---|
| Operating Temperature Range | -40°C to +70°C |
| Storage Temperature Range | -40°C to +70°C |
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor, Sunlight Resistance, Oil Resistance |
|---|---|
| Flammability / Reaction to Fire | OFCR, FT4 |
| ICEA Compliance | S-104-696 |
Product Notes
| Notes | Ozone, Hydraulic fluid resistant |
|---|
History
| Update and Revision | Revision Number: 0.21 Revision Date: 09-07-2025 |
|---|
Resources
Belden TF-3BB-004-RI5 technical datasheetBelden Fiber Optic Catalog - AmericasIndustrial Fiber CatalogMarineTuff Offshore & Marine CableOptical Fiber Cable Reference Guide - IECBelden MarineTuff LSZH Breakout Fiber Optic CablesBelden Indoor/Outdoor Hybrid Breakout CablesMore Fiber Connections are Coming. Are you Prepared?Achieving Polarity in Advanced Fiber InfrastructuresIndustrial Ethernet: Selecting Fiber Cabling & Connectivity