Belden Store
1888ENC

Product Number: 1888ENC

Category 7A Enhanced Cable, 4 Pair, S/FTP, LSZH Indoor IEC60332-3-24

Category 7A Enhanced Premise Horizontal Cable (1300MHz), 4-Pair, 22 AWG solid bare copper conductors, S/FTP, Foam Polyethylene insulation, each pair with Beldfoil® shield, overall tinned copper braid shield (50% coverage), LSZH jacket IEC60332-3-24

Availability
Global
Status
Discontinued

Ships from and sold by A5 IT.

Specifications

Product Overview

Suitable ApplicationsHorizontal and building backbone cable; Support current and future Category 6a, 7 and 7a applications, such as: 25GBase-T (25 Gigabit Ethernet), 10GBase - T (10 Gigabit Ethernet), 1000Base - T (Gigabit Ethernet), 100 Base - T, 10 Base - T, FDDI, ATM

Product Life Cycle

Life CycleDiscontinued - the product is no longer manufactured

Construction Details

Inner Shield Table NotesAluminum facing outside
Overall Cable Diameter (Nominal)8.7 mm (0.34 in)

Conductor

ElementIndividual Shielded Pair
Size22 AWG
StrandingSolid
MaterialBC - Bare Copper
No. of Pairs4

Insulation

ElementIndividual Shielded Pair
MaterialPE - Polyethylene (Foam)
Nom. Insulation Diameter1.5 mm (0.059 in)
Color CodeWhite / Blue, White / Orange, White / Green, White / Brown

Cable Core

Description4 shielded pairs twisted together

Inner Shield

ElementIndividual Shielded Pair
Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%

Outer Shield

Shield TypeBraid
MaterialTinned Copper (TC)
Coverage50%

Outer Jacket

MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Nom. Diameter8.7 mm (0.34 in)
RipcordYes

Electrical Characteristics

High Frequency Table NotesLimits below 4MHz and above 1000 MHz are for information only; Reference standard: IEC 61156-5
Transfer Impedance ClassGrade 1
Screening ClassType I
Screening Table NotesCoupling Attenuation

Electricals

Max. Conductor DCR95 Ohm/km (29 Ohm/1000ft)
Max. Mutual Capacitance56 pF/m (17 pF/ft)
Max. Capacitance Unbalance160 pF/100m
Nom. Characteristic Impedance100 Ohm

Delay

Max. Delay Skew25 ns/100m
Nom. Velocity of Prop.73%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Min. PSANEXT [dB]Min. PSAACRF [dB]Min. TCL [dB]Min. ELTCTL [dB]
12.1 dB/100m787575.972.978752067674023
43.7 dB/100m787574.371.378752367673415
105.8 dB/100m787572.269.275.372.32567673010.9
167.3 dB/100m787570.767.771.268.2256767285.1
31.210.3 dB/100m787567.764.765.462.423.66763.325.2
62.514.6 dB/100m787563.460.459.456.421.56757.322
10018.5 dB/100m75.472.456.953.955.352.320.16753.220
15523.2 dB/100m72.569.549.346.351.548.518.86749.418.1
25029.7 dB/100m69.466.439.736.747.344.317.36745.216
50042.8 dB/100m64.961.922.219.241.338.317.36739.2
60047.1 dB/100m63.760.716.613.639.736.717.365.837.6
100061.9 dB/100m60.457.435.332.315.162.533.2
130071.4 dB/100m58.755.723.520.513.960.830.9

Transfer Impedance

FrequencyMax. Transfer Impedance
1 MhzMax. 10 mOhm/m
10 MhzMax. 10 mOhm/m
30 MhzMax. 30 mOhm/m
100 MhzMax. 100 mOhm/m

Voltage

Voltage Rating72 V DC

Mechanical Characteristics

Max. Pull Tension105 N (23.6 lbf)
Bulk Cable Weight82 kg/km

Temperature

Operating-30°C to +60°C
Installation0°C To +50°C

Bend Radius

Stationary Min.35 mm (1.4 in)
Installation Min.70 mm

Standards and Compliance

Environmental SuitabilityIndoor
Flammability / Reaction to FireIEC 60332-1-2, IEC 60332-3-24
IEEE CompliancePoE: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Data CategoryCategory 7A
TIA/EIA ComplianceANSI/TIA 568.2-D
ISO/IEC ComplianceISO/IEC 11801-1
CENELEC ComplianceEN 50173-1, Segregation class according EN50174-2 = d
European Halogen Free StandardsIEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3, IEC 61034-2 - Smoke Density Min. Transmittance = 60%
European Directive ComplianceEU CE Mark
UK Regulation ComplianceUKCA Mark

Product Notes

NotesElectrical values are expected performance based on cable testing and representative performance within a typical Belden system.

History

Update and RevisionRevision Number: 0.291 Revision Date: 02-26-2026

Resources