Belden Store
BeldenOSP6F

Product Number: OSP6F

Category 6 OSP Cable, 4 Pair, F/UTP, Gel Filled

Category 6 Cable (350MHz), OSP Rated, 4-Pair, 23 AWG Solid Bare Copper Conductors, F/UTP, Gel-Filled, Polyethylene Jacket

Availability
Americas
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

OSP6F is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCOrder
OSP6F 0101000BlackReel1,000 ft612825400868Order online

Specifications

Product Overview

Suitable ApplicationsOSP-Outside, Premise Horizontal Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, PoE++, PoE+, PoE, Noisy Environments
PatentThis product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents .

Construction Details

WaterblockingGel Filled
Overall Cable Diameter (Nominal)0.360 in (9.14 mm)

Conductor

Size23 AWG
StrandingSolid
MaterialBC - Bare Copper
No. of Pairs4

Insulation

MaterialPO - Polyolefin
Color CodeWhite & Blue, White & Orange, White & Green, White & Brown

Inner Jacket

MaterialPE - Polyethylene
Nom. Diameter0.26 in (6.6 mm)

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type26 AWG (7x34) TC

Outer Jacket

SeparatorCenter Member (Patented X-Spline®), EquiBlockTM Barrier Technology
MaterialPO - Polyolefin
Nom. Diameter0.360 in (9.14 mm)
RipcordYes

Electrical Characteristics

Electricals

Max. Conductor DCR93.8 Ohm/km (28.6 Ohm/1000ft)
Max. Capacitance Unbalance160 pF/100m

Delay

Frequency100 MHz
Max. Delay Skew45 ns/100m
Nom. Velocity of Prop.65%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation) [dB/100m]Min. NEXT [dB]Min. PSNEXT [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted) [Ohm]Max./Min. Fitted Impedance [Ohm]Min. TCL [dB]Min. ELTCTL [dB]
12.074.372.370.367.864.820.0100 ± 15100 ± 1540.035.0
43.865.363.359.555.752.723.0100 ± 15100 ± 1540.023.0
85.360.858.853.449.746.724.5100 ± 15100 ± 1540.016.9
106.059.357.351.447.844.825.0100 ± 15100 ± 1540.015.0
167.656.354.346.743.740.725.0100 ± 15100 ± 1538.010.9
208.554.852.844.341.738.725.0100 ± 15100 ± 1537.09.0
259.553.351.341.839.836.824.3100 ± 15100 ± 1536.07.0
31.2510.751.949.939.237.934.923.6100 ± 15100 ± 1535.15.1
62.515.447.445.430.031.828.821.5100 ± 15100 ± 1532.0
10019.844.342.322.527.824.820.1100 ± 15100 ± 1530.0
15525.241.539.514.323.920.918.8100 ± 22100 ± 1528.1
20029.039.837.88.821.718.718.0100 ± 22100 ± 1527.0
25032.838.336.33.519.816.817.3100 ± 32100 ± 1526.0

Voltage

Voltage Rating300 V

Mechanical Characteristics

Max. Pull Tension25 lbs (11 kg)
Bulk Cable Weight49 lbs/1000ft (73 kg/km)

Temperature

Operating-40°C To +75°C
Installation-40°C To +60°C
Storage-40°C To +75°C

Bend Radius

Stationary Min.3.0 in (76 mm)
Installation Min.3.75 in (95.3 mm)

Standards and Compliance

Environmental SuitabilityOutdoor, Outdoor, Sunlight Resistance, Aerial - When supported by messenger wire
CPR ComplianceCPR Euroclass: Fca; CPR UKCA Class: Fca
IEEE ComplianceIEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Data CategoryCategory 6
TIA/EIA ComplianceANSI/TIA-568.2-D Category 6
ISO/IEC Compliance11801 ed 2.2 (2011) Class E
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2017-07-10
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesElectrical values are expected performance based on cable testing and representative performance within a typical Belden system. Cable not guaranteed to meet TIA 568.2 specification for delay above lengths of 90m. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Fully Water Blocked. Suitable for burial or use in outdoor wet locations. Not recommended for Direct Burial applications without additional crush and impact protection. Additional crush and impact protection would include cable armoring, installation in conduit or installation with over top barriers per Belden Technical Bulletin T/8-6. Belden recommends using an entrance demarcation point when transitioning inside buildings with gel-filled OSP cables due to the cable design containing gel specific for wet outdoor environments. The suggested transition point is the REVConnect core coupler, part number RVACPKUBK-S1.

History

Update and RevisionRevision Number: 0.546 Revision Date: 08-17-2026

Resources

Related category 6 cable