DataTuffTM Industrial Ethernet CAT6 4x2x23AWG/1 S/FTP Fire Resistant Anti-Rodent and Water- block
23 AWG solid bare copper conductors, Polyethylene insulation, Mica Glass Tape Fire Protection, S/FTP, Fire Reistant, Individual AL-mylar tape shield +Tinned Copper Braid, Central Drain Wire, Mica Glass Tape and Water Blocking tape, LSZH Jacket, Anti-Rodent and Water- block
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Suitable Applications | Industrial Ethernet Cat 6 connection with Fire Resistant capability |
|---|
Construction Details
Conductor
| Element | Conductor(s) |
|---|---|
| Size | 23 AWG |
| Stranding | Solid |
| Material | BC - Bare Copper |
| No. of Pairs | 4 |
Insulation
| Material | PE - Polyethylene |
|---|---|
| Nom. Insulation Diameter | 1.58 mm (0.0622 in) |
| Color Code | Blue & White with Blue Strip, Orange & White with Orange Strip, Green & White with Green Strip, Brown & White with Brown Strip |
| Notes | Fire Protection Barrier: Mica glass Tape(MGT) |
Inner Shield
| Element | Shield Type | Material | Coverage | Drainwire Type | Notes |
|---|---|---|---|---|---|
| Individual Pair | Tape | Bi-Laminate (Alum+Poly) | 26 AWG (Solid) TC | All four pairs laid up together, bound by a fire-protection barrier of mica-glass tape (MGT) | |
| Overall | Braid | Tinned Copper (TC) | 60% | Water-blocking tape is wrapped over the braid shielding |
Outer Jacket
| Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
|---|---|
| Nom. Diameter | 11.90 mm (0.4685 in) |
Electrical Characteristics
Electricals
| Max. Conductor DCR | 73.2 Ohm/km @ 20 Deg. C |
|---|---|
| Nom. Characteristic Impedance | 100 Ohm |
Delay
| Max. Delay Skew | 45 ns/70m |
|---|
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] |
|---|---|---|---|---|---|---|
| 4 | 3.8 dB/70m | 65.3 | 63.3 | 55.8 | 52.8 | 23.0 |
| 10 | 6.0 dB/70m | 59.3 | 57.3 | 47.8 | 44.8 | 25.0 |
| 20 | 8.5 dB/70m | 54.8 | 52.8 | 41.8 | 38.8 | 25.0 |
| 25 | 9.5 dB/70m | 54.3 | 51.3 | 39.8 | 36.8 | 24.3 |
| 31.25 | 10.7 dB/70m | 51.9 | 49.9 | 37.9 | 34.9 | 23.6 |
| 62.5 | 15.4 dB/70m | 47.4 | 45.4 | 31.9 | 28.9 | 21.5 |
| 100 | 19.8 dB/70m | 44.3 | 42.3 | 27.8 | 24.8 | 20.1 |
| 250 | 32.8 dB/70m | 38.3 | 36.3 | 19.8 | 16.8 | 17.3 |
Voltage
| UL Voltage Rating | 60 V |
|---|
Mechanical Characteristics
| Temperature Table Notes | Temperature range : -40°C To +80°C |
|---|
Standards and Compliance
| Environmental Suitability | UV Resistance, Oil Resistance |
|---|---|
| Flammability / Reaction to Fire | IEC 60332-1-2, IEC 60332-3-22, IEC 60331-23 |
| Data Category | Category 6 |
| TIA/EIA Compliance | ANSI/TIA 568.2-D |
| ISO/IEC Compliance | IEC 11801 |
| European Halogen Free Standards | IEC 60754-1 - Halogen Amount = 0.50%, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
History
| Update and Revision | Revision Number: 0.16 Revision Date: 02-26-2026 |
|---|
Resources
Related category 6 cable

2140A
Category 6 Indoor/Outdoor Cable, 4 Pair, F/UTP, OSP/CM-ST1
23 · BC - Bare Copper · PO - Polyolefin

50106F
Paired - Category 6 F/UTP Unbonded – Pair Cable
23 AWG · BC - Bare Copper · PO - Polyolefin · PVC - Polyvinyl Chloride

50106U
Paired - Category 6 U/UTP Unbonded – Pair Cable
24 AWG · BC - Bare Copper · PO - Polyolefin · PVC - Polyvinyl Chloride

50106UAL
Paired - Category 6 U/UTP Unbonded – Halogen Free Cable
23 AWG · BC - Bare Copper · PO - Polyolefin · LSZH - Low Smoke Zero Halogen (Flame Retardant)