Category 6 OSP Cable, 4 Pair, F/UTP, Gel Free
Category 6 Premise Horizontal Cable, OSP Rated, 4 Pair, 23 AWG Solid Bare Copper Conductors, F/UTP - Foil Shielded, Gel Free
- Availability
- Global
- Status
- Active
- Orderable items
- 1
Part numbers
DOSP6F is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Putup Type | Length | Order |
|---|---|---|---|---|
| DOSP6F 0101000 | Black | Reel | 1,000 ft | Order online |
Specifications
Product Overview
| Suitable Applications | OSP-Outside Plant, Premise Horizontal Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, Surveillance, PoE++, PoE+, PoE, Noisy Environments |
|---|---|
| Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents . |
Construction Details
| Overall Cable Diameter (Nominal) | 0.29 in (7.4 mm) |
|---|
Conductor
| Size | 23 |
|---|---|
| Stranding | Solid |
| Material | BC - Bare Copper |
| No. of Pairs | 4 |
Insulation
| Material | PO - Polyolefin |
|---|---|
| Color Code | White & Blue, White & Orange, White & Green, White & Brown |
Outer Shield
| Shield Type | Tape |
|---|---|
| Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire Type | 26 AWG (7x34) TC |
Outer Jacket
| Separator | Center Member (Patented T-Spline®), EquiBlockTM Barrier Technology |
|---|---|
| Material | PO - Polyolefin |
| Nom. Diameter | 0.29 in (7.4 mm) |
| Ripcord | Yes |
Electrical Characteristics
Electricals
| Max. Conductor DCR | 82 Ohm/km (25 Ohm/1000ft) |
|---|---|
| Max. Capacitance Unbalance | 45 pF/100m |
Delay
| Frequency | 100 MHz |
|---|---|
| Max. Delay | 537.6 ns/100m |
| Max. Delay Skew | 45 ns/100m |
| Nom. Velocity of Prop. | 68% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) [dB/100m] | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) [Ohm] |
|---|---|---|---|---|---|---|---|
| 1 | 2.0 | 74.3 | 72.3 | 67.8 | 64.8 | 20 | 100 ± 15 |
| 4 | 3.8 | 65.3 | 63.3 | 55.8 | 52.7 | 23 | 100 ± 15 |
| 8 | 5.3 | 60.8 | 58.8 | 49.7 | 46.7 | 24.5 | 100 ± 15 |
| 10 | 6 | 59.3 | 57.3 | 47.8 | 44.8 | 25 | 100 ± 15 |
| 16 | 7.6 | 56.2 | 54.3 | 43.7 | 40.7 | 25 | 100 ± 15 |
| 20 | 8.5 | 54.8 | 52.8 | 41.8 | 38.8 | 25 | 100 ± 15 |
| 25 | 9.5 | 53.3 | 51.3 | 39.8 | 36.8 | 24.3 | 100 ± 15 |
| 31.25 | 10.7 | 51.9 | 49.9 | 37.9 | 34.9 | 23.6 | 100 ± 15 |
| 62.5 | 15.4 | 47.4 | 45.4 | 31.9 | 28.9 | 21.5 | 100 ± 15 |
| 100 | 19.8 | 44.3 | 42.3 | 27.8 | 24.8 | 20.1 | 100 ± 20 |
| 155 | 25.2 | 41.5 | 39.5 | 23.9 | 20.9 | 18.8 | 100 ± 20 |
| 200 | 29.0 | 39.8 | 37.8 | 21.8 | 18.8 | 18 | 100 ± 20 |
| 250 | 32.8 | 38.3 | 36.3 | 19.8 | 16.8 | 17.3 | 100 ± 20 |
Voltage
| Voltage Rating | 300 V |
|---|
Mechanical Characteristics
| Max. Pull Tension | 25 lbs (11 kg) |
|---|---|
| Bulk Cable Weight | 33 lbs/1000ft (49 kg/km) |
Temperature
| Operating | -20°C To +70°C |
|---|---|
| Installation | 0°C To +60°C |
| Storage | -40°C To +75°C |
Bend Radius
| Installation Min. | 2.9 in (74 mm) |
|---|
Standards and Compliance
| Environmental Suitability | Outdoor - Water Exposure, Outdoor |
|---|---|
| IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
| Data Category | Category 6 |
| TIA/EIA Compliance | ANSI/TIA-568.2-D Category 6 |
| ISO/IEC Compliance | 11801 ed 2.2 (2011) Class EA |
| CENELEC Compliance | Segregation class according EN50174-2 = a |
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Suitable for burial or use in outdoor wet locations. Not recommended for Direct Burial applications without additional crush and impact protection. Additional crush and impact protection would include cable armoring, installation in conduit or installation with over top barriers per Belden Technical Bulletin T/8-6. Cable jacket system is specially designed to protect cable core. Cable contains no water-blocking tapes, gels, or powders. Install in accordance with all applicable electrical codes. Maintain jacket integrity throughout installation process. Do not allow water or fluids to penetrate jacket sheath or to enter ends of cable. Ensure ends of cable will be protected from water/fluids after installation. Belden recommends using an entrance demarcation point when transitioning inside buildings with OSP cables. The suggested transition point is the REVConnect core coupler, part number RVACPKUBK-S1. |
|---|
History
| Update and Revision | Revision Number: 0.168 Revision Date: 02-20-2026 |
|---|
Resources
Related category 6 cable

2140A
Category 6 Indoor/Outdoor Cable, 4 Pair, F/UTP, OSP/CM-ST1
23 · BC - Bare Copper · PO - Polyolefin
1 item

50106F
Paired - Category 6 F/UTP Unbonded – Pair Cable
23 AWG · BC - Bare Copper · PO - Polyolefin · PVC - Polyvinyl Chloride
6 items