Belden Store
Belden7972A

Product Number: 7972A

DataTuff® 6, 4 Bonded-Pr #24 Str BC, PP Ins, PVC Jkt, CMR, CMX Outdoor

Industrial Ethernet Cat 6, 4 Bonded-Pair 24AWG (Stranded) Bare Copper, PP Insulation, PVC Outer Jacket, CMR, CMX Outdoor

Availability
Global
Status
Active
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

7972A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Order
7972A 0101000Order online
7972A 0105000Order online

Specifications

Product Overview

Suitable ApplicationsHarsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc.

Construction Details

Bonded-PairYes
Overall Cable Diameter (Nominal)0.290 in (7.37 mm)

Conductor

Size24 AWG
Stranding7x32
MaterialBC - Bare Copper
No. of Pairs4

Insulation

MaterialPO - Polyolefin
Color CodeWhite/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown

Outer Jacket

SeparatorDielectric Tape (Patented)
MaterialPVC - Polyvinyl Chloride
Nom. Diameter0.290 in (7.37 mm)
RipcordYes

Electrical Characteristics

Electricals

Max. Conductor DCR140 Ohm/km (43 Ohm/1000ft)
Max. Capacitance Unbalance330 pF/100m

Delay

Frequency100 MHz
Max. Delay537 ns/100m
Max. Delay Skew45 ns/100m
Nom. Velocity of Prop.69%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted) [Ohm]Max./Min. Fitted Impedance [Ohm]Min. TCL [dB]Min. ELTCTL [dB]
12.4 dB/100m74.372.371.969.967.864.820100 ± 15100 ± 1540.035.0
44.5 dB/100m65.363.360.858.855.852.723100 ± 15100 ± 1540.023.0
86.4 dB/100m60.858.854.452.449.746.724.5100 ± 15100 ± 1540.016.9
107.1 dB/100m59.357.352.250.247.844.825100 ± 15100 ± 1540.015.0
169.1 dB/100m56.254.347.145.143.740.725100 ± 15100 ± 1538.010.9
2010.2 dB/100m54.852.844.642.641.838.825100 ± 15100 ± 1537.09.0
2511.4dB/100m53.351.341.939.939.836.824.2100 ± 15100 ± 1536.07.0
31.2512.8 dB/100m51.949.939.137.137.934.923.3100 ± 15100 ± 1535.15.1
62.518.5 dB/100m47.445.428.926.931.928.920.7100 ± 15100 ± 1532.0
10023.8 dB/100m44.342.320.518.527.824.819.0100 ± 15100 ± 1530.0
15530.2 dB/100m41.539.511.39.323.920.917.4100 ± 20100 ± 1528.1
20034.8 dB/100m39.837.85.03.021.818.816.4100 ± 20100 ± 1527.0
25039.4 dB/100m38.336.319.816.815.6100 ± 20100 ± 1526.0

Voltage

UL Voltage Rating300 V (CMR), 300 V (CMX-Outdoor)

Mechanical Characteristics

Max. Pull Tension40 lbs (18 kg)
Bulk Cable Weight29 lbs/1000ft (43 kg/km)

Temperature

UL Temperature90°C
Operating-40°C To +90°C
Storage-40°C To +90°C

Bend Radius

Stationary Min.1.2 in (30 mm)

Standards and Compliance

Environmental SuitabilityIndoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Oil Resistance
Flammability / Reaction to FireUL1666 Riser, FT4
CPR ComplianceCPR Euroclass: Fca
NEC / UL ComplianceArticle 800, CMR, CMX-Outdoor
Data CategoryCategory 6
TIA/EIA ComplianceANSI/TIA-568.2-D Category 6
ISO/IEC ComplianceISO/IEC 11801-1, IEC 61156-5
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2022-04-27
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesJacket sequentially marked at 2 ft. intervals.

History

Update and RevisionRevision Number: 0.16 Revision Date: 02-20-2026

Resources

Related category 6 cable