Belden7967A
DataTuff Ind. Cat. 6 OSP Cable, 4 Pair, F/UTP, Gel Filled, 23AWG. Oil Res II
DataTuff Industrial Category 6 Cable (350MHz), OSP Rated, 4-Pair, 23 AWG Solid Bare Copper Conductors, F/UTP, Gel-Filled, LLDPE Jacket, Shield, CPE Jacket
- Availability
- Americas
- Status
- Active
Specifications
Product Overview
| Suitable Applications | OSP-Outside, Premise Horizontal Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, PoE++, PoE+, PoE, Noisy Environments |
|---|---|
| Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents . |
Construction Details
| Waterblocking | Gel Filled |
|---|---|
| Overall Cable Diameter (Nominal) | 0.360 in (9.14 mm) |
Conductor
| Size | 23 |
|---|---|
| Stranding | Solid |
| Material | BC - Bare Copper |
| No. of Pairs | 4 |
Insulation
| Material | PO - Polyolefin |
|---|---|
| Color Code | White & Blue, White & Orange, White & Green, White & Brown |
Inner Jacket
| Material | PE - Polyethylene |
|---|---|
| Nom. Diameter | 0.26 in (6.6 mm) |
Outer Shield
| Shield Type | Tape |
|---|---|
| Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire Type | 26 AWG (7x34) TC |
Outer Jacket
| Material | CPE - Chlorinated Polyethylene |
|---|---|
| Nom. Diameter | 0.360 in (9.14 mm) |
| Ripcord | Yes |
Electrical Characteristics
Electricals
| Max. Conductor DCR | 93.8 Ohm/km (28.6 Ohm/1000ft) |
|---|---|
| Max. Capacitance Unbalance | 160 pF/100m |
Delay
| Frequency | 100 MHz |
|---|---|
| Max. Delay Skew | 45 ns/100m |
| Nom. Velocity of Prop. | 65% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) [dB/100m] | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) [Ohm] | Max./Min. Fitted Impedance [Ohm] | Min. TCL [dB] | Min. ELTCTL [dB] |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2.0 | 74.3 | 72.3 | 70.3 | 67.8 | 64.8 | 20.0 | 100 ± 15 | 100 ± 15 | 40.0 | 35.0 |
| 4 | 3.8 | 65.3 | 63.3 | 59.5 | 55.7 | 52.7 | 23.0 | 100 ± 15 | 100 ± 15 | 40.0 | 23.0 |
| 8 | 5.3 | 60.8 | 58.8 | 53.4 | 49.7 | 46.7 | 24.5 | 100 ± 15 | 100 ± 15 | 40.0 | 16.9 |
| 10 | 6.0 | 59.3 | 57.3 | 51.4 | 47.8 | 44.8 | 25.0 | 100 ± 15 | 100 ± 15 | 40.0 | 15.0 |
| 16 | 7.6 | 56.3 | 54.3 | 46.7 | 43.7 | 40.7 | 25.0 | 100 ± 15 | 100 ± 15 | 38.0 | 10.9 |
| 20 | 8.5 | 54.8 | 52.8 | 44.3 | 41.7 | 38.7 | 25.0 | 100 ± 15 | 100 ± 15 | 37.0 | 9.0 |
| 25 | 9.5 | 53.3 | 51.3 | 41.8 | 39.8 | 36.8 | 24.3 | 100 ± 15 | 100 ± 15 | 36.0 | 7.0 |
| 31.25 | 10.7 | 51.9 | 49.9 | 39.2 | 37.9 | 34.9 | 23.6 | 100 ± 15 | 100 ± 15 | 35.1 | 5.1 |
| 62.5 | 15.4 | 47.4 | 45.4 | 30.0 | 31.8 | 28.8 | 21.5 | 100 ± 15 | 100 ± 15 | 32.0 | |
| 100 | 19.8 | 44.3 | 42.3 | 22.5 | 27.8 | 24.8 | 20.1 | 100 ± 15 | 100 ± 15 | 30.0 | |
| 155 | 25.2 | 41.5 | 39.5 | 14.3 | 23.9 | 20.9 | 18.8 | 100 ± 22 | 100 ± 15 | 28.1 | |
| 200 | 29.0 | 39.8 | 37.8 | 8.8 | 21.7 | 18.7 | 18.0 | 100 ± 22 | 100 ± 15 | 27.0 | |
| 250 | 32.8 | 38.3 | 36.3 | 3.5 | 19.8 | 16.8 | 17.3 | 100 ± 32 | 100 ± 15 | 26.0 |
Voltage
| Voltage Rating | 300 V |
|---|
Mechanical Characteristics
| Max. Pull Tension | 25 lbs (11 kg) |
|---|---|
| Bulk Cable Weight | 49 lbs/1000ft (73 kg/km) |
Temperature
| Operating | -40°C To +75°C |
|---|---|
| Installation | -40°C To +60°C |
| Storage | -40°C To +75°C |
Bend Radius
| Stationary Min. | 3.0 in (76 mm) |
|---|---|
| Installation Min. | 3.75 in (95.3 mm) |
Standards and Compliance
| Environmental Suitability | Outdoor, Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance, Aerial - When supported by messenger wire |
|---|---|
| CPR Compliance | CPR Euroclass: Fca; CPR UKCA Class: Fca |
| IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
| Data Category | Category 6 |
| TIA/EIA Compliance | ANSI/TIA-568.2-E Category 6 |
| ISO/IEC Compliance | 11801 ed 2.2 (2011) Class E |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2017-07-10 |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Cable not guaranteed to meet TIA 568.2 specification for delay above lengths of 90m. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Fully Water Blocked. Suitable for burial or use in outdoor wet locations. Not recommended for Direct Burial applications without additional crush and impact protection. Additional crush and impact protection would include cable armoring, installation in conduit or installation with over top barriers per Belden Technical Bulletin T/8-6. Belden recommends using an entrance demarcation point when transitioning inside buildings with gel-filled OSP cables due to the cable design containing gel specific for wet outdoor environments. The suggested transition point is the REVConnect core coupler, part number RVACPKUBK-S1. |
|---|
History
| Update and Revision | Revision Number: 0.25 Revision Date: 08-17-2026 |
|---|
Resources
Related category 6 cable

2140A
Category 6 Indoor/Outdoor Cable, 4 Pair, F/UTP, OSP/CM-ST1
23 · BC - Bare Copper · PO - Polyolefin
1 item

50106F
Paired - Category 6 F/UTP Unbonded – Pair Cable
23 AWG · BC - Bare Copper · PO - Polyolefin · PVC - Polyvinyl Chloride
6 items

50106U
Paired - Category 6 U/UTP Unbonded – Pair Cable
24 AWG · BC - Bare Copper · PO - Polyolefin · PVC - Polyvinyl Chloride
4 items

50106UAL
Paired - Category 6 U/UTP Unbonded – Halogen Free Cable
23 AWG · BC - Bare Copper · PO - Polyolefin · LSZH - Low Smoke Zero Halogen (Flame Retardant)
5 items