PLENUM, 2C #18, Str, FEP, 300 V, CMP 150C, CSA C(UL) TYPE CMP, CSA FT6

PLENUM, 2 Conductor 18 AWG (19/30) TC - Tinned Copper, FEP Insulation, Overall Aluminum/Polyester Shield, Red FEP Outer Jacket, CMP 150C, CSA C(UL) TYPE CMP, CSA FT6 C(UL) TYPE CMP, FT6 UL FT6; CSA FT6

Availability
Global
Status
Active
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

M613242 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthOrder
M613242 RD005RedReel100 ftOrder online
M613242 RD001RedReel1,000 ftOrder online

Specifications

Product Overview

Suitable ApplicationsData, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Construction Details

Overall Cable Diameter (Nominal)0.162 in (4.11 mm)

Conductor

ElementConductor(s)
No. of Elements2
Size18 AWG
Stranding19x30
MaterialTC - Tinned Copper

Insulation

ElementConductor(s)
MaterialFEP - Fluorinated Ethylene Propylene
Nom. Thickness0.007 in (0.18 mm)
Nom. Insulation Diameter0.064 in (1.6 mm)
Color CodeBlack, Red

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type20 AWG (19x32) TC

Outer Jacket

MaterialFEP - Fluorinated Ethylene Propylene
Nom. Thickness0.015 in (0.38 mm)
Nom. Diameter0.162 in (4.11 mm)

Electrical Characteristics

Nom Outer Shield DCR77 Ohm/1000ft (250 Ohm/km)

Electricals

ElementConductor(s)
Nom. Capacitance Cond-to-Cond39 pF/ft (130 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)70 pF/ft (230 pF/m)
Nom. Characteristic Impedence38 Ohm
Nom. Inductance0.14 μH/ft (0.46 μH/m)

Voltage

UL Voltage Rating300 V (CMP)

Mechanical Characteristics

Max. Pull Tension39 lbs (18 kg)

Temperature

UL Temperature150°C
Operating-80°C To +150°C

Bend Radius

Stationary Min.1.6 in (41 mm)

Standards and Compliance

Environmental SuitabilityIndoor
Flammability / Reaction to FireUL1685 FT6 Loading, FT6
NEC / UL ComplianceArticle 800, CMP
CEC / C(UL) ComplianceCMP.
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesAlpha Wire -* P/N M613242 2C 18 AWG EXXXXXX SHIELDED 150C CMP (UL) C(UL) CE ROHS

History

Update and RevisionRevision Number: 0.111 Revision Date: 06-30-2026

Resources

Related multi-conductor cable