Belden Store
BeldenM39115

Product Number: M39115

CONTROL, 2C #20, Str, PVC, 300 V, ITC 105C, SUN RES, PLTC 105C, CSA C(UL) TYPE CMG, CSA FT4

CONTROL, 2 Conductor 20 AWG (19/32) TC - Tinned Copper, PVC Insulation, Overall Aluminum/Polyester Shield, Slate PVC Outer Jacket, ITC 105C, SUN RES, PLTC 105C, CSA C(UL) TYPE CMG, CSA FT4 C(UL) TYPE CMG, FT4 UL FT4; CSA FT4

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

M39115 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthOrder
M39115 SL005SlateReel100 ftOrder online

Specifications

Product Overview

Suitable ApplicationsData, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Construction Details

Overall Cable Diameter (Nominal)0.227 in (5.77 mm)

Conductor

ElementConductor(s)
No. of Elements2
Size20 AWG
Stranding19x32
MaterialTC - Tinned Copper

Insulation

ElementConductor(s)
MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.016 in (0.41 mm)
Nom. Insulation Diameter0.072 in (1.8 mm)
Color CodeBlack, Red

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type22 AWG (7x30) TC

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.038 in (0.97 mm)
Nom. Diameter0.227 in (5.77 mm)

Electrical Characteristics

Nom Outer Shield DCR117 Ohm/1000ft (384 Ohm/km)

Electricals

ElementConductor(s)
Nom. Capacitance Cond-to-Cond46 pF/ft (150 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)83 pF/ft (270 pF/m)
Nom. Characteristic Impedence46 Ohm
Nom. Inductance0.19 μH/ft (0.62 μH/m)

Voltage

UL Voltage Rating300 V (PLTC, ITC, CMG, CL3)

Mechanical Characteristics

Max. Pull Tension41 lbs (19 kg)

Temperature

UL Temperature105°C
Operating-20°C To +105°C

Bend Radius

Stationary Min.2.3 in (58 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance
Flammability / Reaction to FireUL1685 FT4 Loading, FT4
NEC / UL ComplianceArticle 725, Article 727, Article 800, CMG, PLTC, ITC
CEC / C(UL) ComplianceCMG.
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesAlpha Wire -* P/N M39115 2C 20 AWG SHIELDED EXXXXX (UL) TYPE PLTC/ITC 105C SUN RES OR CL3 105C OR C(UL) CMG 105C FT4 CE ROHS

History

Update and RevisionRevision Number: 0.16 Revision Date: 06-30-2026

Resources

Related multi-conductor cable