Product Number: M1224

HITEMPCTRL, 4C #22, Str, PTFE, 600 V

HITEMPCTRL, 4 Conductor 22 AWG (19/34) SPC - Silver Plated Copper, PTFE Insulation, Overall Silver Plated Copper Shield, White PTFE Tape Outer Jacket

Availability
Global
Status
Active
Orderable items
3

Ships from and sold by A5 IT.

Part numbers

M1224 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthOrder
M1224 WH199WhiteCut to Length1 ftOrder online
M1224 WH005WhiteReel100 ftOrder online
M1224 WH001WhiteReel1,000 ftOrder online

Specifications

Product Overview

Suitable ApplicationsData, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Construction Details

Overall Cable Diameter (Nominal)0.167 in (4.24 mm)

Conductor

ElementConductor(s)
No. of Elements4
Size22 AWG
Stranding19x34
MaterialSC - Silvered Copper

Insulation

ElementConductor(s)
MaterialPTFE - Polytetrafluoroethylene
Nom. Thickness0.009 in (0.23 mm)
Nom. Insulation Diameter0.050 in (1.3 mm)
Color CodeWhite, Black, Red, Green

Outer Shield

Shield TypeBraid
MaterialSilvered Copper (SC)
Coverage85%

Outer Jacket

MaterialPTFE - Polytetrafluoroethylene
Nom. Thickness0.012 in (0.30 mm)
Nom. Diameter0.167 in (4.24 mm)

Electrical Characteristics

Electricals

ElementConductor(s)
Nom. Capacitance Cond-to-Cond24.1 pF/ft (79.1 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)43 pF/ft (140 pF/m)
Nom. Inductance0.17 μH/ft (0.56 μH/m)

Voltage

Voltage Rating600 V (MIL-SPEC)

Mechanical Characteristics

Max. Pull Tension58 lbs (26 kg)

Temperature

Operating-55°C To +200°C

Bend Radius

Stationary Min.1.3 in (33 mm)
Installation Min.1.3 in (33 mm)

Standards and Compliance

Environmental SuitabilityIndoor
SustainabilityCA Prop 65
Military ComplianceMIL-W-16878/4
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.46 Revision Date: 06-30-2026