Belden Store
BeldenB964013

Product Number: B964013

EMEA, 1PR #22, Str, PVC, Semi Rigid, 300 V, AWM/STYLE 10002 105C, AWM/STYLE 2464 80C, CM 105C, VW-1, CSA CMG, CSA FT4

EMEA, 1 Pair 22 AWG (7/30) TC - Tinned Copper, PVC, Semi Rigid Insulation, Overall Tinned Copper Shield, Grey PVC Outer Jacket, AWM/STYLE 10002 105C, AWM/STYLE 2464 80C, CM 105C, VW-1, CSA CMG, CSA FT4 CMG, FT4 UL FT4, VW-1; CSA FT4; EN 60332-1 Flame Behavior; EN 60332-2 Flame Behavior

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

B964013 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthOrder
B964013 GE321GreyReel164 ftOrder online

Specifications

Product Overview

Suitable ApplicationsData, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Construction Details

Overall Cable Diameter (Nominal)0.189 in (4.80 mm)

Conductor

ElementPair(s)
No. of Elements1
Size22 AWG
Stranding7x30
MaterialTC - Tinned Copper

Insulation

ElementPair(s)
MaterialSR-PVC - Polyvinyl Chloride (Semi-Rigid)
Nom. Thickness0.010 in (0.25 mm)
Nom. Insulation Diameter0.050 in (1.3 mm)
Color CodeWhite-Black

Outer Shield

Shield TypeBraid
MaterialTinned Copper (TC)
Coverage85%
Drainwire Type22 AWG (7x30) TC

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.032 in (0.81 mm)
Nom. Diameter0.189 in (4.80 mm)
RipcordYes

Electrical Characteristics

Electricals

ElementPair(s)
Nom. Capacitance Cond-to-Cond38 pF/ft (120 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)68 pF/ft (220 pF/m)
Nom. Characteristic Impedence49 Ohm
Nom. Inductance0.18 μH/ft (0.59 μH/m)

Voltage

UL Voltage Rating300 V (CM, CMG, AWM 2464)

Mechanical Characteristics

Max. Pull Tension33 lbs (15 kg)

Temperature

UL Temperature105°C
Operating-30°C To +105°C

Bend Radius

Stationary Min.1.9 in (48 mm)
Installation Min.2.8 in (71 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor
Flammability / Reaction to FireUL1685 FT4 Loading, FT4, IEC 60332-1-2, IEC 60332-2-2
NEC / UL ComplianceArticle 800, CMG, CM
AWM ComplianceAWM 2464
CEC / C(UL) ComplianceCMG.
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesAlpha Wire -* P/N B964013 1PR 22 AWG 0.35MM2 (22AWG) (UL) TYPE CM 105C OR AWM 2464 VW-1 --- LLXXXXXX CSA 105C TYPE CMG FT4 CE ROHS (SEQ METERS)

History

Update and RevisionRevision Number: 0.11 Revision Date: 06-30-2026