Belden Store
9609

Product Number: 9609

RS232, #24-4c, SR-PVC, O/A Foil+Braid, PVC Jkt, CMG

Computer EIA RS-232 Cable, 24 AWG stranded (7x32) tinned copper conductors, semi-rigid PVC insulation, overall Beldfoil® (100% coverage) + tinned copper braid shield (65% coverage), PVC jacket.

Availability
Global
Status
Active
Orderable items
3

Ships from and sold by A5 IT.

Part numbers

9609 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCOrder
9609 060100ChromeReel100 ft612825256311Order online
9609 060500ChromeReel500 ft612825256335Order online
9609 0601000ChromeReel1,000 ft612825256328Order online

Specifications

Product Overview

Suitable ApplicationsRS-232 applications; Computer Communications; Low Voltage Analog signals (4-20ma, 0-10v, ...); Low Voltage Digital control (24v, ...); Line Level Audio; Panel Wiring

Construction Details

Overall Cable Diameter (Nominal)0.200 in (5.08 mm)

Conductor

ElementConductor(s)
No. of Elements4
Size24 AWG
Stranding7x32
MaterialTC - Tinned Copper

Insulation

ElementConductor(s)
MaterialSR-PVC - Polyvinyl Chloride (Semi-Rigid)
Nom. Thickness0.011 in (0.28 mm)
Color CodeBlack, White, Red, Green

Outer Shield

Shield TypeMaterialCoverage
TapeBi-Laminate (Alum+Poly)100%
BraidTinned Copper (TC)65%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.035 in (0.89 mm)
Nom. Diameter0.200 in (5.08 mm)

Electrical Characteristics

Nom Outer Shield DCR9.8 Ohm/1000ft (32 Ohm/km)

Electricals

ElementConductor(s)
Nom. Conductor DCR25 Ohm/1000ft (82 Ohm/km)
Nom. Capacitance Cond-to-Cond35 pF/ft (110 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)65 pF/ft (210 pF/m)
Max. Current1.8 Amps per Conductor at 25oC

Voltage

UL Voltage Rating300 V (CMG), 300 V (UL AWM 2464)

Mechanical Characteristics

Max. Pull Tension39 lbs (18 kg)
Bulk Cable Weight25 lbs/1000ft (37 kg/km)

Temperature

UL Temperature80°C (UL AWM 2464)
Operating-30°C to +80°C

Bend Radius

Stationary Min.2.0 in (51 mm)
Installation Min.2.0 in (51 mm)

Standards and Compliance

Environmental SuitabilityIndoor
Flammability / Reaction to FireUL1685 FT4 Loading, FT4
CPR ComplianceCPR Euroclass: Eca
NEC / UL ComplianceArticle 800, CMG
AWM ComplianceAWM 2464
CEC / C(UL) ComplianceCMG.
European Directive ComplianceEU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.347 Revision Date: 09-07-2025
FootnoteC - CRATE REEL PUT-UP.

Resources