Product Overview

Suitable Applicationsfire alarms; indoor applications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage control (24v, ...)

Construction Details

Overall Cable Diameter (Nominal)0.301 in

Conductor

ElementConductor(s)
No. of Elements4
Size16 AWG
StrandingSolid
MaterialBC - Bare Copper

Insulation

ElementConductor(s)
MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.018 in (0.46 mm)
Nom. Insulation Diameter0.087 in (2.2 mm)
Color CodeBlack, Red, Yellow, Blue

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type22 AWG (7x30) TC

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.042 in (1.1 mm)
Nom. Diameter0.301 in

Electrical Characteristics

Nom Outer Shield DCR9.2 Ohm/1000ft (30 Ohm/km)

Electricals

ElementConductor(s)
Nom. Conductor DCR4.1 Ohm/1000ft
Nom. Capacitance Cond-to-Cond53 pF/ft (170 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)98 pF/ft (320 pF/m)
Max. Current9.6 Amps per Conductor at 25oC

Voltage

UL Voltage Rating300 V

Mechanical Characteristics

Max. Pull Tension133 lbs (60.3 kg)
Bulk Cable Weight65 lbs/1000ft

Temperature

UL Temperature105°C
Operating-40°C To +105°C

Bend Radius

Stationary Min.3.01 in (76.5 mm)
Installation Min.3.01 in

Standards and Compliance

Environmental SuitabilityIndoor, Indoor, Sunlight Resistance
Flammability / Reaction to FireUL1666 Riser, FT4
CPR ComplianceCPR Euroclass: Eca
NEC / UL ComplianceArticle 760, Article 800, CMR, FPLR
AWM ComplianceAWM 2464
CEC / C(UL) ComplianceCMG, FAS105.
European Directive ComplianceEU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)California State Fire Marshall