Electronic, 4 C #18 Sol BC, PVC Ins, OS, Red PVC Jkt, FPLR
Electronic, 4 Conductor 18AWG (Solid) Bare Copper, PVC Insulation, Overall Beldfoil® Shield, Red PVC Outer Jacket, FPLR
- Availability
- Global
- Status
- Active
- Orderable items
- 1
Part numbers
9578 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | UPC | Footnote | Order |
|---|---|---|---|---|
| 9578 0021000 | Red | 612825256199 | C | Order online |
Specifications
Product Overview
| Suitable Applications | fire alarms; indoor applications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage control (24v, ...) |
|---|
Construction Details
| Overall Cable Diameter (Nominal) | 0.263 in |
|---|
Conductor
| Element | Conductor(s) |
|---|---|
| No. of Elements | 4 |
| Size | 18 AWG |
| Stranding | Solid |
| Material | BC - Bare Copper |
Insulation
| Element | Conductor(s) |
|---|---|
| Material | PVC - Polyvinyl Chloride |
| Nom. Thickness | 0.017 in (0.43 mm) |
| Nom. Insulation Diameter | 0.077 in (2.0 mm) |
| Color Code | Black, Red, Yellow, Blue |
Outer Shield
| Shield Type | Tape |
|---|---|
| Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire Type | 22 AWG (7x30) TC |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Thickness | 0.037 in (0.94 mm) |
| Nom. Diameter | 0.263 in |
Electrical Characteristics
| Nom Outer Shield DCR | 10.3 Ohm/1000ft (33.8 Ohm/km) |
|---|
Electricals
| Element | Conductor(s) |
|---|---|
| Nom. Conductor DCR | 6.4 Ohm/1000ft |
| Nom. Capacitance Cond-to-Cond | 43 pF/ft (140 pF/m) |
| Nom. Capacitance Cond-to-Other (Conds + Shield) | 79.2 pF/ft (260 pF/m) |
| Nom. Inductance | 0.169 μH/ft (0.554 μH/m) |
| Max. Current | 6.4 Amps per Conductor at 25oC |
Voltage
| UL Voltage Rating | 300 V |
|---|
Mechanical Characteristics
| Max. Pull Tension | 87.5 lbs (39.7 kg) |
|---|---|
| Bulk Cable Weight | 48 lbs/1000ft |
Temperature
| UL Temperature | 105°C |
|---|---|
| Operating | -40°C To +105°C |
Bend Radius
| Stationary Min. | 2.63 in (66.8 mm) |
|---|---|
| Installation Min. | 2.63 in |
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance |
|---|---|
| Flammability / Reaction to Fire | UL1666 Riser, FT4 |
| NEC / UL Compliance | Article 760, Article 800, CMR, FPLR |
| AWM Compliance | AWM 2464 |
| CEC / C(UL) Compliance | CMG, FAS105. |
| European Directive Compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Other Standard Compliance(s) | California State Fire Marshall |
History
| Update and Revision | Revision Number: 0.402 Revision Date: 09-07-2025 |
|---|---|
| Footnote | C - CRATE REEL PUT-UP. |
Resources
Related multi-conductor cable
1064
Communication and Control, 4C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
4 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride
1065
Communication and Control, 5C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
5 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride
1067
Communication and Control, 7C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
7 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride
1069
Communication and Control, 9C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
9 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride