ECOCABLE, 19C #20, Str, MPPE, 600 V, AWM/STYLE 11231 105C, AWM/STYLE 21915 105C, Horizontal Flame, CSA C(RU) AWM I/II A/B FT2
ECOCABLE, 19 Conductor 20 AWG (7/28) TC - Tinned Copper, MPPE Insulation, Overall Aluminum/Polyester Shield, Slate MPPE Outer Jacket, AWM/STYLE 11231 105C, AWM/STYLE 21915 105C, Horizontal Flame, CSA C(RU) AWM I/II A/B FT2 C(RU) AWM I/II A/B FT2
- Availability
- Global
- Status
- Active
- Orderable items
- 1
Part numbers
77212 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Putup Type | Length | Order |
|---|---|---|---|---|
| 77212 SL199 | Slate | Cut to Length | 1 ft | Order online |
Specifications
Product Overview
| Suitable Applications | Data, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. |
|---|
Construction Details
| Overall Cable Diameter (Nominal) | 0.386 in (9.80 mm) |
|---|
Conductor
| Element | Conductor(s) |
|---|---|
| No. of Elements | 19 |
| Size | 20 AWG |
| Stranding | 7x28 |
| Material | TC - Tinned Copper |
Insulation
| Element | Conductor(s) |
|---|---|
| Material | mPPE - Modified Polyphenylene Ether |
| Nom. Thickness | 0.010 in (0.25 mm) |
| Nom. Insulation Diameter | 0.058 in (1.5 mm) |
| Color Code | Black, Brown, Red, Orange, Yellow, Green, Blue, Violet, Slate, White, White/Black, White/Brown, White/Red, White/Orange, White/Yellow, White/Green, White/Blue, White/Violet, White/Slate |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Braid | Bi-Laminate (Alum+Poly) | 100% | 20 AWG (7x28) TC |
| Braid | Tinned Copper (TC) | 70% |
Outer Jacket
| Material | mPPE - Modified Polyphenylene Ether |
|---|---|
| Nom. Thickness | 0.032 in (0.81 mm) |
| Nom. Diameter | 0.386 in (9.80 mm) |
| Ripcord | Yes |
Electrical Characteristics
| Nom Outer Shield DCR | 204 Ohm/1000ft (669 Ohm/km) |
|---|
Electricals
| Element | Conductor(s) |
|---|---|
| Nom. Capacitance Cond-to-Cond | 27 pF/ft (89 pF/m) |
| Nom. Capacitance Cond-to-Other (Conds + Shield) | 49 pF/ft (160 pF/m) |
| Nom. Inductance | 0.17 μH/ft (0.56 μH/m) |
Voltage
| UL Voltage Rating | 600 V (AWM 11231, AWM 21915), 600 V (CSA AWM) |
|---|
Mechanical Characteristics
| Max. Pull Tension | 36 lbs (16 kg) |
|---|
Temperature
| UL Temperature | 105°C |
|---|---|
| Operating | -50°C To +105°C |
Bend Radius
| Stationary Min. | 3.9 in (99 mm) |
|---|
Standards and Compliance
| Environmental Suitability | Indoor |
|---|---|
| Sustainability | CA Prop 65 |
| Flammability / Reaction to Fire | FT2 |
| AWM Compliance | AWM 21915, AWM I/II A/B |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK Regulation Compliance | UKCA Mark |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
Product Notes
| Notes | Alpha Wire -* P/N 77212 19C 20 AWG ECOCABLE(R) RU AWM 21915 105C 600V C(RU) AWM I/II A/B FT2 600V 105C CE ROHS (SEQ FOOTAGE) |
|---|
History
| Update and Revision | Revision Number: 0.17 Revision Date: 06-30-2026 |
|---|
Resources
Related multi-conductor cable
1064
Communication and Control, 4C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
4 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride
1065
Communication and Control, 5C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
5 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride
1067
Communication and Control, 7C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
7 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride
1069
Communication and Control, 9C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
9 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride