XTRAGUARD 1, 3C #20, Str, PVC, Semi Rigid, 300 V, AWM/STYLE 10002 105C, AWM/STYLE 2343 80C, CM 105C, VW-1, AWM/STYLE 2517 105C, SUN RES, CSA CMG, CSA FT4
XTRAGUARD 1, 3 Conductor 20 AWG (7/28) TC - Tinned Copper, PVC, Semi Rigid Insulation, Overall Aluminum/Polyester Shield, Slate PVC Outer Jacket, AWM/STYLE 10002 105C, AWM/STYLE 2343 80C, CM 105C, VW-1, AWM/STYLE 2517 105C, SUN RES, CSA CMG, CSA FT4 CMG, FT4 UL FT4, VW-1; CSA FT4; EN 60332-1 Flame Behavior; EN 60332-2 Flame Behavior
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Suitable Applications | Industrial control systems, raceways, cable trays, and ducts; instrumentation and control circuits; analog and digital signals (4–20 mA, 0–10 V); PLC and DCS systems; sensors, encoders, solenoids, valves, actuators, and positioners. |
|---|
Construction Details
| Overall Cable Diameter (Nominal) | 0.259 in (6.58 mm) |
|---|
Conductor
| Element | Conductor(s) |
|---|---|
| No. of Elements | 3 |
| Size | 20 AWG |
| Stranding | 7x28 |
| Material | TC - Tinned Copper |
Insulation
| Element | Conductor(s) |
|---|---|
| Material | SR-PVC - Polyvinyl Chloride (Semi-Rigid) |
| Nom. Thickness | 0.010 in (0.25 mm) |
| Nom. Insulation Diameter | 0.058 in (1.5 mm) |
| Color Code | Black, Brown, Red |
Outer Shield
| Shield Type | Tape |
|---|---|
| Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire Type | 20 AWG (7x28) TC |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Thickness | 0.063 in (1.6 mm) |
| Nom. Diameter | 0.259 in (6.58 mm) |
| Ripcord | Yes |
Electrical Characteristics
Electricals
| Element | Conductor(s) |
|---|
Voltage
| UL Voltage Rating | 300 V (MTW, AWM 20811, AWM 2501) |
|---|---|
| Voltage Rating | 600 V (CSA AWM) |
Mechanical Characteristics
| Max. Pull Tension | 99 lbs (45 kg) |
|---|
Temperature
| UL Temperature | 105°C |
|---|---|
| Operating | -35°C To +105°C |
Bend Radius
| Stationary Min. | 2.6 in (66 mm) |
|---|
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance |
|---|---|
| Sustainability | CA Prop 65 |
| Flammability / Reaction to Fire | UL1685 FT4 Loading, FT4, IEC 60332-1-2, IEC 60332-2-2 |
| NEC / UL Compliance | Article 800, CMG, CM |
| AWM Compliance | AWM 2343 AWM 2517 |
| CEC / C(UL) Compliance | CMG. |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK Regulation Compliance | UKCA Mark |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
Product Notes
| Notes | Alpha Wire -* P/N 5560/3C 3C 20 AWG XTRAGUARD(R) 1 SHIELDED (UL) TYPE CM 105C SUN RES OR AWM 2343 80C 300V OR AWM 2517 105C 300V VW-1 --- LLXXXXXX CSA 105C TYPE CMG FT4 CE ROHS OIL RESISTANT (SEQ FOOTAGE) |
|---|
History
| Update and Revision | Revision Number: 0.16 Revision Date: 06-30-2026 |
|---|
Resources
Related multi-conductor cable
1064
Communication and Control, 4C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
4 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride
1065
Communication and Control, 5C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
5 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride
1067
Communication and Control, 7C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
7 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride
1069
Communication and Control, 9C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
9 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride