Belden Store
Belden55462

Product Number: 55462

XTRAGUARD 5, 2C #20, Str, FEP, 300 V, CMP 150C, AWM/STYLE 20229 150C, CSA CMP, CSA FT6

XTRAGUARD 5, 2 Conductor 20 AWG (7/28) TC - Tinned Copper, FEP Insulation, Overall Aluminum/Polyester Shield, Natural/Translucent FEP Outer Jacket, CMP 150C, AWM/STYLE 20229 150C, CSA CMP, CSA FT6 CMP, FT6 UL FT6; CSA FT6

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

55462 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthOrder
55462 NA199NaturalCut to Length1 ftOrder online

Specifications

Product Overview

Suitable ApplicationsData, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Construction Details

Overall Cable Diameter (Nominal)0.182 in (4.62 mm)

Conductor

ElementConductor(s)
No. of Elements2
Size20 AWG
Stranding7x28
MaterialTC - Tinned Copper

Insulation

ElementConductor(s)
MaterialFEP - Fluorinated Ethylene Propylene
Nom. Thickness0.010 in (0.25 mm)
Nom. Insulation Diameter0.058 in (1.5 mm)
Color CodeBlack, Brown

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type20 AWG (7x28) TC

Outer Jacket

MaterialFEP - Fluorinated Ethylene Propylene
Nom. Thickness0.027 in (0.69 mm)
Nom. Diameter0.182 in (4.62 mm)
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR76 Ohm/1000ft (250 Ohm/km)

Electricals

ElementConductor(s)
Nom. Capacitance Cond-to-Cond27 pF/ft (89 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)49 pF/ft (160 pF/m)
Nom. Characteristic Impedence55 Ohm
Nom. Inductance0.17 μH/ft (0.56 μH/m)

Voltage

UL Voltage Rating300 V (CMP, AWM 20229)

Mechanical Characteristics

Max. Pull Tension71 lbs (32 kg)

Temperature

UL Temperature150°C
Operating-80°C To +200°C

Bend Radius

Stationary Min.1.8 in (46 mm)

Standards and Compliance

Environmental SuitabilityIndoor
SustainabilityCA Prop 65
Flammability / Reaction to FireUL1685 FT6 Loading, FT6
NEC / UL ComplianceArticle 800, CMP
AWM ComplianceAWM 20229
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesAlpha Wire -* P/N 55462 2C 20 AWG XTRAGUARD(R) 5 - 20 AWG SHIELDED 150C (UL) CMP OR AWM 20229 -- LLXXXXXX CSA CMP FT6 CE ROHS

History

Update and RevisionRevision Number: 0.13 Revision Date: 06-30-2026