Belden Store
Belden55116

Product Number: 55116

XTRAGUARD 5, 6C #24, Str, FEP, 300 V, CMP 150C, AWM/STYLE 20229 150C, CSA CMP, CSA FT6

XTRAGUARD 5, 6 Conductor 24 AWG (7/32) TC - Tinned Copper, FEP Insulation, Overall Aluminum/Polyester Shield, Natural/Translucent FEP Outer Jacket, CMP 150C, AWM/STYLE 20229 150C, CSA CMP, CSA FT6 CMP, FT6 UL FT6; CSA FT6

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

55116 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthOrder
55116 NA199NaturalCut to Length1 ftOrder online

Specifications

Product Overview

Suitable ApplicationsData, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Construction Details

Overall Cable Diameter (Nominal)0.221 in (5.61 mm)

Conductor

ElementConductor(s)
No. of Elements6
Size24 AWG
Stranding7x32
MaterialTC - Tinned Copper

Insulation

ElementConductor(s)
MaterialFEP - Fluorinated Ethylene Propylene
Nom. Thickness0.010 in (0.25 mm)
Nom. Insulation Diameter0.044 in (1.1 mm)
Color CodeBlack, Brown, Red, Orange, Yellow, Green

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
BraidBi-Laminate (Alum+Poly)100%24 AWG (7x32) TC
BraidTinned Copper (TC)70%

Outer Jacket

MaterialFEP - Fluorinated Ethylene Propylene
Nom. Thickness0.027 in (0.69 mm)
Nom. Diameter0.221 in (5.61 mm)
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR41 Ohm/1000ft (130 Ohm/km)

Electricals

ElementConductor(s)
Nom. Capacitance Cond-to-Cond19.1 pF/ft (62.7 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)34 pF/ft (110 pF/m)
Nom. Inductance0.19 μH/ft (0.62 μH/m)

Voltage

UL Voltage Rating300 V (CMP, AWM 20229)

Mechanical Characteristics

Max. Pull Tension107 lbs (48.5 kg)

Temperature

UL Temperature150°C
Operating-80°C To +200°C

Bend Radius

Stationary Min.2.2 in (56 mm)

Standards and Compliance

Environmental SuitabilityIndoor
SustainabilityCA Prop 65
Flammability / Reaction to FireUL1685 FT6 Loading, FT6
NEC / UL ComplianceArticle 800, CMP
AWM ComplianceAWM 20229
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesAlpha Wire -* P/N 55116 6C 24 AWG XTRAGUARD(R) 5 - 24 AWG SHIELDED 150C (UL) CMP OR AWM 20229 -- LLXXXXXX CSA CMP FT6 CE ROHS

History

Update and RevisionRevision Number: 0.15 Revision Date: 06-30-2026

Resources

Related multi-conductor cable