Safe-T-Line, 1 P #14 Sol BC, Silicone Ins, LSZH Jkt, FPLR, CWZ, PH120
Safe-T-Line 1 TW Pair x AWG14 (Solid SBC) Fire resistant Multi-conductor, BS 6387 CWZ, EN 50200 PH120, EN60331-2 , Unshielded, Ceramifiable Silicone insulation, Low Smoke Zero Halogen Jacket
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Suitable Applications | Fire Resistant Applications With Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, ...), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners |
|---|
Construction Details
| Outer Jacket1 Table Notes | Highly Flame Retardant Non-Halogenated Polyolefin |
|---|
Conductor
| Element | Pair(s) |
|---|---|
| Size | 14 AWG |
| Stranding | Solid |
| Material | BC - Bare Copper |
Insulation
| Element | Pair(s) |
|---|---|
| Material | Silicone Rubber |
| Nom. Thickness | 0.034 in (0.86 mm) |
| Nom. Insulation Diameter | 0.133 in (3.38 mm) |
| Color Code | Black, Red |
Outer Shield
| Shield Type | Tape |
|---|---|
| Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
Outer Jacket
| Material | PO - Polyolefin |
|---|---|
| Nom. Thickness | 0.045 in (1.1 mm) |
| Nom. Diameter | 0.359 in (9.12 mm) |
Electrical Characteristics
Electricals
| Nom. Conductor DCR | 2.67 Ohm/1000ft (8.76 Ohm/km) |
|---|---|
| Max. Current | 25 Amps per Conductor at 30oC |
Voltage
| UL Voltage Rating | 300 V |
|---|
Mechanical Characteristics
| Max. Pull Tension | 99.4 lbs (45.1 kg) |
|---|---|
| Bulk Cable Weight | 65 lbs/1000ft (97 kg/km) |
Temperature
| UL Temperature | 105°C |
|---|---|
| Operating | -20°C to +105°C |
Bend Radius
| Stationary Min. | 3.58 in (90.9 mm) |
|---|---|
| Installation Min. | 3.58 in (90.9 mm) |
| Flexing Min. | 2.864 in (72.75 mm) |
Standards and Compliance
| Environmental Suitability | Indoor Riser, Indoor, Outdoor, Non-Halogenated, Sunlight Resistance |
|---|---|
| Flammability / Reaction to Fire | UL 1666 Riser, 1202, IEC 60331-21, BS EN 50200 PH120 |
| NEC / UL Compliance | Article 760, FPLR, ITC, PLTC |
| European Directive Compliance | EU Directive 2011/65/EU (RoHS 2) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Other Standard Compliance(s) | BS 6387 CWZ, EN50200 PH120 |
| Plenum Number | No |
History
| Update and Revision | Revision Number: 0.42 Revision Date: 07-21-2026 |
|---|
Resources
Related multi-conductor cable
Belden1064
1064
Communication and Control, 4C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
4 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride
3 items
Belden1065
1065
Communication and Control, 5C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
5 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride
3 items
Belden1067
1067
Communication and Control, 7C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
7 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride
3 items
Belden1069
1069
Communication and Control, 9C #16, Str, PVC, 600 V, AWM/STYLE 2463 80C, VW-1
9 · 16 AWG · TC - Tinned Copper · PVC - Polyvinyl Chloride
2 items