Belden Store
Belden45493

Product Number: 45493

XTRAGUARD 4, 3PR #24, Str, TPE, 300 V, AWM/STYLE 20237 125C, AWM/STYLE 21918 125C, SUN RES, CSA C(RU) AWM I/II A/B FT1, CSA SUN RES (Black only)

XTRAGUARD 4, 3 Pair 24 AWG (7/32) TC - Tinned Copper, TPE Insulation, Overall Aluminum/Polyester Shield, Slate TPE Outer Jacket, AWM/STYLE 20237 125C, AWM/STYLE 21918 125C, SUN RES, CSA C(RU) AWM I/II A/B FT1, CSA SUN RES (Black only) C(RU) AWM I/II A/B FT1, SUN RES (Black only)

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Product Overview

Suitable ApplicationsData, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Construction Details

Overall Cable Diameter (Nominal)0.290 in (7.37 mm)

Conductor

ElementPair(s)
No. of Elements3
Size24 AWG
Stranding7x32
MaterialTC - Tinned Copper

Insulation

ElementPair(s)
MaterialTPE - Thermoplastic Elastomer
Nom. Thickness0.016 in (0.41 mm)
Nom. Insulation Diameter0.056 in (1.4 mm)
Color CodeWhite-Black, White-Brown, White-Red

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type24 AWG (7x32) TC

Outer Jacket

MaterialTPE - Thermoplastic Elastomer
Nom. Thickness0.042 in (1.1 mm)
Nom. Diameter0.290 in (7.37 mm)
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR159 Ohm/1000ft (522 Ohm/km)

Electricals

ElementPair(s)
Nom. Capacitance Cond-to-Cond15 pF/ft (49 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)27 pF/ft (89 pF/m)
Nom. Characteristic Impedence110 Ohm
Nom. Inductance0.22 μH/ft (0.72 μH/m)

Voltage

UL Voltage Rating300 V (AWM 20237, AWM 21918)
Voltage Rating300 V (CSA AWM)

Mechanical Characteristics

Max. Pull Tension51 lbs (23 kg)

Temperature

UL Temperature125°C
Operating-50°C To +125°C

Bend Radius

Stationary Min.2.9 in (74 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance - Black only
SustainabilityCA Prop 65
Flammability / Reaction to FireFT1
AWM ComplianceAWM 20237 AWM 21918, AWM I/II A/B
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesAlpha Wire -* P/N 45493 3PR 24 AWG XTRAGUARD(R) 4 RU AWM 20237/21918 125C 300V SUN RES OR CRU AWM I/II A/B 125C 300 VOLTS FT1 P-07-KA140023-MSHA CE ROHS (SEQ FOOTAGE)

History

Update and RevisionRevision Number: 0.14 Revision Date: 06-30-2026

Resources

Related multi-conductor cable