Belden Store
Belden45129/15

Product Number: 45129/15

XTRAGUARD 4, 15PR #22, Str, TPE, 300 V, AWM/STYLE 20237 125C, PLTC 105C, AWM/STYLE 21918 125C, SUN RES, CSA C(RU) AWM I/II A/B FT1, CSA SUN RES (Black only)

XTRAGUARD 4, 15 Pair 22 AWG (7/30) TC - Tinned Copper, TPE Insulation, Overall Aluminum/Polyester Shield, Slate TPE Outer Jacket, AWM/STYLE 20237 125C, PLTC 105C, AWM/STYLE 21918 125C, SUN RES, CSA C(RU) AWM I/II A/B FT1, CSA SUN RES (Black only) C(RU) AWM I/II A/B FT1, SUN RES (Black only)

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

45129/15 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthOrder
45129/15 BK199BlackCut to Length1 ftOrder online

Specifications

Product Overview

Suitable ApplicationsData, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Construction Details

Overall Cable Diameter (Nominal)0.632 in (16.1 mm)

Conductor

ElementPair(s)
No. of Elements15
Size22 AWG
Stranding7x30
MaterialTC - Tinned Copper

Insulation

ElementPair(s)
MaterialTPE - Thermoplastic Elastomer
Nom. Thickness0.016 in (0.41 mm)
Nom. Insulation Diameter0.062 in (1.6 mm)
Color CodeWhite-Black, White-Brown, White-Red, White-Orange, White-Yellow, White-Green, White-Blue, White-Violet, White-Slate, Black-Brown, Black-Red, Black-Orange, Black-Yellow, Black-Green, Black-Blue

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeBi-Laminate (Alum+Poly)100%22 AWG (7x30) TC
BraidTinned Copper (TC)70%

Outer Jacket

MaterialTPE - Thermoplastic Elastomer
Nom. Thickness0.065 in (1.7 mm)
Nom. Diameter0.632 in (16.1 mm)
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR19 Ohm/1000ft (62 Ohm/km)

Electricals

ElementPair(s)
Nom. Capacitance Cond-to-Cond15.1 pF/ft (49.5 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)27 pF/ft (89 pF/m)
Nom. Characteristic Impedence105 Ohm
Nom. Inductance0.2 μH/ft (0.66 μH/m)

Voltage

UL Voltage Rating300 V (PLTC, AWM 20237, AWM 21918)
Voltage Rating300 V (CSA AWM)

Mechanical Characteristics

Max. Pull Tension67 lbs (30 kg)

Temperature

UL Temperature125°C
Operating-50°C To +125°C

Bend Radius

Stationary Min.6.3 in (160 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance - Black only
SustainabilityCA Prop 65
Flammability / Reaction to FireFT1
NEC / UL ComplianceArticle 725, PLTC
AWM ComplianceAWM 20237 AWM 21918, AWM I/II A/B
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesAlpha Wire -* P/N 45129/15 15PR 22 AWG XTRAGUARD(R) 4 (UL) TYPE PLTC 105C SUN RES OR AWM 20237/21918 125C 300 V OR CRU AWM I/II A/B 125C 300 V FT1 P-07-KA140023-MSHA CE ROHS (SEQ FOOTAGE)

History

Update and RevisionRevision Number: 0.14 Revision Date: 06-30-2026

Resources