Belden Store
Belden25430/4

Product Number: 25430/4

XTRAGUARD 2, 4C #18, Str, PVC, 600 V, AWM/STYLE 20669 90C, VW-1, AWM/STYLE 1015 105C, CSA C(RU) AWM I/II A/B, CSA FT1, CSA TEW

XTRAGUARD 2, 4 Conductor 18 AWG (16/30) TC - Tinned Copper, PVC Insulation, Overall Aluminum/Polyester Shield, Slate Polyurethane (TPU) Outer Jacket, AWM/STYLE 20669 90C, VW-1, AWM/STYLE 1015 105C, CSA C(RU) AWM I/II A/B, CSA FT1, CSA TEW C(RU) AWM I/II A/B, FT1, TEW UL FT1, VW-1; CSA FT1

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

25430/4 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthOrder
25430/4 SL199SlateCut to Length1 ftOrder online

Specifications

Product Overview

Suitable ApplicationsData, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Construction Details

Overall Cable Diameter (Nominal)0.403 in (10.2 mm)

Conductor

ElementConductor(s)
No. of Elements4
Size18 AWG
Stranding16x30
MaterialTC - Tinned Copper

Insulation

ElementConductor(s)
MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.032 in (0.81 mm)
Nom. Insulation Diameter0.111 in (2.82 mm)
Color CodeBlack, Brown, Red, Orange

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type18 AWG (16x30) TC

Outer Jacket

MaterialPUR - Polyurethane
Nom. Thickness0.063 in (1.6 mm)
Nom. Diameter0.403 in (10.2 mm)
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR56 Ohm/1000ft (180 Ohm/km)

Electricals

ElementConductor(s)
Nom. Capacitance Cond-to-Cond32 pF/ft (100 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)58 pF/ft (190 pF/m)
Nom. Inductance0.22 μH/ft (0.72 μH/m)

Voltage

UL Voltage Rating600 V (AWM 20669)
Voltage Rating600 V (CSA AWM, TEW)

Mechanical Characteristics

Max. Pull Tension10.6 lbs (4.81 kg)

Temperature

UL Temperature105°C
Operating-30°C To +90°C

Bend Radius

Stationary Min.4.0 in (100 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor
SustainabilityCA Prop 65
Flammability / Reaction to FireUL1685 FT1 Loading, FT1
AWM ComplianceAWM 20669, AWM I/II A/B
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesAlpha Wire -* P/N 25430/4 4C 18 AWG XTRAGUARD(R) 2 RU AWM 20669 VW-1 OR CRU AWM I/II A/B 90C 600 VOLTS FT1 CE ROHS (SEQ FOOTAGE)

History

Update and RevisionRevision Number: 0.47 Revision Date: 06-30-2026

Resources

Related multi-conductor cable