Belden Store
Belden1738C

Product Number: 1738C

Communication and Control, 4C #22, Str, PVC, 300 V, AWM/STYLE 2095 80C, CM 75C, VW-1, CSA C(UL) TYPE CMG, CSA FT4

Communication and Control, 4 Conductor 22 AWG (7/30) TC - Tinned Copper, PVC Insulation, Overall Bare Copper Shield, Slate PVC Outer Jacket, AWM/STYLE 2095 80C, CM 75C, VW-1, CSA C(UL) TYPE CMG, CSA FT4 C(UL) TYPE CMG, FT4 UL FT4, VW-1; CSA FT4

Availability
Global
Status
Active
Orderable items
3

Ships from and sold by A5 IT.

Part numbers

1738C is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthOrder
1738C SL005SlateReel100 ftOrder online
1738C SL002SlateReel500 ftOrder online
1738C SL001SlateReel1,000 ftOrder online

Specifications

Product Overview

Suitable ApplicationsIndustrial control systems, raceways, cable trays, and ducts; instrumentation and control circuits; analog and digital signals (4–20 mA, 0–10 V); PLC and DCS systems; sensors, encoders, solenoids, valves, actuators, and positioners.

Construction Details

Overall Cable Diameter (Nominal)0.215 in (5.46 mm)

Conductor

ElementConductor(s)
No. of Elements4
Size22 AWG
Stranding7x30
MaterialTC - Tinned Copper

Insulation

ElementConductor(s)
MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.016 in (0.41 mm)
Nom. Insulation Diameter0.062 in (1.6 mm)
Color CodeBlack, Red, White, Green

Outer Shield

Shield TypeBraid
MaterialBare Copper (BC)
Coverage75%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.020 in (0.51 mm)
Nom. Diameter0.215 in (5.46 mm)

Electrical Characteristics

Nom Outer Shield DCR64 Ohm/1000ft (210 Ohm/km)

Electricals

ElementConductor(s)
Nom. Capacitance Cond-to-Cond35 pF/ft (110 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)63 pF/ft (210 pF/m)
Nom. Inductance0.2 μH/ft (0.66 μH/m)

Voltage

UL Voltage Rating300 V (CMG, CM, AWM 2095)

Mechanical Characteristics

Max. Pull Tension55 lbs (25 kg)

Temperature

UL Temperature80°C
Operating-20°C To +80°C

Standards and Compliance

Environmental SuitabilityIndoor
SustainabilityCA Prop 65
Flammability / Reaction to FireUL1685 FT4 Loading, FT4
NEC / UL ComplianceArticle 800, CMG, CM
AWM ComplianceAWM 2095
CEC / C(UL) ComplianceCMG.
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesAlpha Wire -* P/N 1738C 4C 22 AWG SHIELDED 75C (UL) TYPE CM OR AWM 2095 OR C(UL) 60C TYPE CMG FT4 CE ROHS

History

Update and RevisionRevision Number: 0.119 Revision Date: 06-30-2026

Resources

Related multi-conductor cable