Belden Store
RTA1C1

Product Number: RTA1C1

RailTuffTM Thin wall cable 300V 1 C 1.0 mm2 Str TC, XLPO Ins

RailTuffTM Thin wall cable 300V 1 Core 1.0 mm2 Stranded Tinned Copper, XLPO Insulation

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Product Overview

Suitable ApplicationsApplicable for fixed or moderate flexing wiring inside Railway Rolling Stock like High-Speed Trains (CRH, Shinkansen, ICE, TGV), Metro, locomotives, and trolley buses, etc

Construction Details

Insulation Table NotesD.C. stability at 300Vdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown
Overall Cable Diameter (Nominal)1.77 ± 0.03 mm

Conductor

Size1 mm2
Stranding37x0.18 mm
MaterialTC - Tinned Copper

Insulation

MaterialXLP, XLPO, XLPE
Nom. Thickness0.34 mm (0.013 in)
Nom. Insulation Diameter1.77 mm (0.0697 in)
Color CodeWhite#1

Electrical Characteristics

Voltage

Breakdown Voltage2.5kVac/5min

Mechanical Characteristics

Bulk Cable Weight10.6 kg/km (7.12 lbs/1000ft)

Temperature

Operating-40°C to +120°C

Bend Radius

Stationary Min.9 mm (0.35 in)
Installation Min.7 mm (0.28 in)

Standards and Compliance

Flammability / Reaction to FireIEC 60332-1-2, EN 50305
European Halogen Free StandardsIEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3, IEC 61034-2 - Smoke Density Min. Transmittance = 70%

History

Update and RevisionRevision Number: 0.36 Revision Date: 07-07-2026