Video Triax, RG11, #15 Stranded, CL2X
15 AWG stranded (19x27) .064" bare copper conductor, foam HDPE insulation, bare copper braid shields (90% and 80% coverage), PVC jacket (polyethylene insulation between braids).
- Availability
- Global
- Status
- Discontinued
- Orderable items
- 1
Part numbers
9192 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Putup Type | Length | UPC | Footnote | Order |
|---|---|---|---|---|---|---|
| 9192 0041000 | Yellow | Reel | 1,000 ft | 612825225201 | C | Order online |
Specifications
Product Life Cycle
| Life Cycle | Discontinued - the product is no longer manufactured |
|---|---|
| Discontinuation Announcement Date | 1999-02-19 |
Construction Details
| RG Type | 11 |
|---|---|
| Insulation Table Notes | Gas Injected |
Conductor
| Size | 15 |
|---|---|
| Stranding | 19x27 |
| Nom. Diameter | 0.064 in |
| Material | BC - Bare Copper |
Insulation
| Material | PE - Polyethylene (Foam) |
|---|---|
| Nom. Insulation Diameter | 0.312 in (7.92 mm) |
Inner Shield
| Shield Type | Braid |
|---|---|
| Material | Bare Copper (BC) |
| Coverage | 90% |
Inner Jacket
| Material | PE - Polyethylene |
|---|---|
| Nom. Diameter | 0.391 in (9.93 mm) |
Outer Shield
| Outer Shield Type | Braid |
|---|---|
| Material | Bare Copper (BC) |
| Coverage | 90% |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Diameter | 0.52 in |
Electrical Characteristics
| Electrical Characteristics Notes | Nominal Capacitance 1st Shield to 2nd Shield: 205 pf/ft. |
|---|
Return Loss
| Frequency | 5-850 MHz |
|---|---|
| Min. Return Loss | 21 dB |
Attenuation
| Frequency | Nom. Attenuation |
|---|---|
| 1 MHz | 0.1 dB/100ft |
| 3.6 MHz | 0.3 dB/100ft |
| 10 MHz | 0.5 dB/100ft |
| 71.5 MHz | 1.2 dB/100ft |
| 135 MHz | 1.8 dB/100ft |
| 270 MHz | 2.6 dB/100ft |
| 360 MHz | 3.1 dB/100ft |
| 540 MHz | 3.9 dB/100ft |
| 720 MHz | 4.7 dB/100ft |
| 750 MHz | 4.8 dB/100ft |
| 1000 MHz | 5.7 dB/100ft |
Electricals
| Nom. Conductor DCR | 3.1 Ohm/1000ft (10 Ohm/km) |
|---|---|
| Nom. Inner Shield DCR | 1.6 Ohm/1000ft (5.2 Ohm/km) |
| Nom. Outer Shield DCR | 1.6 Ohm/1000ft (5.2 Ohm/km) |
| Nom. Capacitance Cond-to-Shield | 17.3 pF/ft (56.8 pF/m) |
| Nom. Characteristic Impedance | 75 Ohm |
| Nom. Velocity of Prop. | 78% |
Voltage
| UL Voltage Rating | 150 V RMS, 30 V RMS |
|---|---|
| Voltage Rating | 300 V RMS |
Mechanical Characteristics
| Max. Pull Tension | 239 lbs (108 kg) |
|---|---|
| Bulk Cable Weight | 139 lbs/1000ft (207 kg/km) |
Temperature
| UL Temperature | 80°C |
|---|---|
| Operating | -40°C To +75°C |
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor, Indoor |
|---|---|
| Flammability / Reaction to Fire | UL1685 UL Loading, VW-1 |
| CPR Compliance | CPR Euroclass: Eca |
| NEC / UL Compliance | CL2X |
| AWM Compliance | AWM 1641 (30 V 80°C) |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK Regulation Compliance | UKCA Mark |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
History
| Update and Revision | Revision Number: 0.374 Revision Date: 07-30-2026 |
|---|---|
| Footnote | C - CRATE REEL PUT-UP. |
Resources
Related video triax cable

1856A
Triax, RG59, 20 AWG Solid BC, Double 95% BC Braids, Belflex® Jkt
20 AWG · BC - Bare Copper · PE - Polyethylene (Foam) · PVC - Polyvinyl Chloride

1857A
Triax, RG59, 22 AWG Str BC, Double 95% BC Braids, Belflex® Jkt, Flexible
22 AWG · BC - Bare Copper · PE - Polyethylene (Foam) · PVC - Polyvinyl Chloride

1858A
Video Triax, RG11, #15 Stranded, Belflex PVC jacket
1 · 15 AWG · BC - Bare Copper · PE - Polyethylene (Foam)

1859A
Triax, RG11, 15 AWG Str BC, Double BC Braids, PVDF Jkt, CMP
15 AWG · BC - Bare Copper · FEP - Fluorinated Ethylene Propylene (Foam) · PVDF - Polyvinylidene Fluoride