Outdoor Tactical (loose jacket, ARAMID) tight buffered distribution cable PUR jacket 4f SM OS2 G.657.A2.
Outdoor Tactical (loose jacket, aramid yarns) tight buffered optical fiber distribution cable with Polyurethane (PUR) outer jacket. 4 fibers SM OS2 G.657.A2.
- Availability
- Global
- Status
- Active
- Orderable items
- 4
Part numbers
GNMTF04 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Putup Type | Length | EAN | Order |
|---|---|---|---|---|---|
| GNMTF04.002100 | Black | Reel | 2,100 m | 8719605128140 | Order online |
| GNMTF04.004100 | Black | Reel | 4,100 m | 8719605181206 | Order online |
| GNMTF04.003100 | Black | Reel | 3,100 m | 8719605188199 | Order online |
| GNMTF04.T03100 | Black | Reel | 3,100 m | 8719605234865 | Order online |
Specifications
Product Overview
| Suitable Applications | For outdoor and indoor use. These metal-free mobile cables have been designed for de-spooling and re-spooling repeatedly. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM Easy to install. Not Recommended for direct burial. |
|---|
Fiber Specifications
| Fiber Type | OS1 |
|---|---|
| Fiber Grade Acc to ITU-T | G.657A2 |
| Fiber Core Diameter | 9 μm |
| Fiber Buffer Material | PA - Polyamide |
| Fiber Buffer Construction | Tight |
| Fiber Buffer Diameter | 0.9 mm |
| Fiber Count | 4 |
| Fiber Color Coding | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown |
Cable Construction
| Cable Core Water Blocking | Waterblocking Aramid Yarns |
|---|
Outer Jacket Specifications
| Jacket Material | PUR - Polyurethane |
|---|---|
| Nom. Diameter | 5.8 mm (0.23 in) |
Optical Characteristics
| Wavelength | Max. Attenuation |
|---|---|
| 1310 nm | 0.50 dB/km |
| 1550 nm | 0.30 dB/km |
| 1625 nm | 0.51 dB/km |
Mechanical Characteristics
| Bulk Cable Weight | 30 kg/km (20 lbs/1000ft) |
|---|
Mechanical Tests
| Description | Tested Standard | Requirement/Value | According to Family Specification |
|---|---|---|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 46.4 mm | |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 23.2 mm | |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 1350 N (303 lbf) | |
| Cable Max. Tensile Strength Operation (Long Term) | 450 N (100 lbf) | ||
| Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 5 kN/m | IEC 60794-2-20 |
| Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 3 kN/m | IEC 60794-2-20 |
Temperature Range
| Installation Temperature Range | -5 °C to +50 °C |
|---|---|
| Operating Temperature Range | -55 °C to +85 °C |
| Storage Temperature Range | -70 °C to +85 °C |
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor |
|---|---|
| ISO/IEC Compliance | IEC 60794 ISO/IEC 11801-1 |
History
| Update and Revision | Revision Number: 0.197 Revision Date: 09-26-2025 |
|---|