Outdoor Tactical tight buffered (core bonded design) PUR jacket 16f SM OS2 G.657.A2.
Outdoor Tactical tight buffered optical fiber cable with core bonded design with Polyurethane (PUR) outer jacket. 16 fibers SM OS2 G.657.A2.
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Environmental Space | Indoor/Outdoor |
|---|---|
| Suitable Applications | For outdoor and indoor use. These metal-free mobile cables have been designed for de-spooling and re-spooling repeatedly. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM Easy to install. Not Recommended for direct burial. Core-bonded Polyurethane jacket providing simple installation. |
Construction
| Fiber Color Code | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua. With Ringmark: BL, OR, GR, BR |
|---|---|
| Cable Core Water Tight | Yes |
| Cable Core Water Blocking | Waterblocking Aramid Yarns |
| Bulk Cable Weight | 64 kg/km |
Fiber Cable Construction
| Fiber Type | OS2 |
|---|---|
| Fiber Grade acc. ITU-T | G.657A2 |
| Fiber Count | 16 |
Buffer Specification
| Fiber Type | OS2 |
|---|---|
| Buffer Construction | Tight |
| Buffer Material | Nylon |
| Buffer Diameter | 0.9 mm |
Physical Specifications
| Type of Armor | Non-Armored |
|---|
Jacket Specifications
| Number of Jackets | Single Jacket |
|---|
Outer Jacket Specifications
Outer Jacket
| Material | PUR - Polyurethane |
|---|---|
| Color | Black |
| Nominal Diameter | 8.3 mm |
| Ripcord | Yes |
Optical Characteristics
| Maximum Attenuation at 1310 nm | 0.40 dB/km |
|---|---|
| Maximum Attenuation at 1550 nm | 0.30 dB/km |
| Maximum Attenuation at 1625 nm | 0.30 dB/km |
Mechanical Characteristics
Mechanical Tests
| Description | Tested Standard | Requirement/Value | According to Family Specification |
|---|---|---|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 66.4 mm | |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 33.2 mm | |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 2250 N (506 lbf) | |
| Cable Max. Tensile Strength Operation (Long Term) | 750 N (169 lbf) | ||
| Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 5 kN/m | IEC 60794-2-20 |
| Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 3 kN/m | IEC 60794-2-20 |
Temperature Range
| Operating Temperature Range | -70 °C to +85 °C |
|---|---|
| Installation Temperature Range | -5 °C to +50 °C |
| Storage Temperature Range | -70 °C to +85 °C |
Product Material
| UL Rating/Flame Test | Non-UL Rated |
|---|
Standards
| IEC Flammability | IEC 60332-1-2 |
|---|---|
| REACH | Compliant |
| ISO/IEC Compliance | IEC 60794, ISO/IEC 11801-1 |
| UV/ Sunlight Protection | Yes |
History
| Update and Revision | Revision Number: 0.55 Revision Date: 09-17-2024 |
|---|