Outdoor Tactical tight buffered (core bonded design) PUR jacket 4f SM OS2 G.657.A2.
Outdoor Tactical tight buffered optical fiber cable with core bonded design with Polyurethane (PUR) outer jacket. 4 fibers SM OS2 G.657.A2.
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Environmental Space | Indoor/Outdoor |
|---|---|
| Suitable Applications | For outdoor and indoor use. These metal-free mobile cables have been designed for de-spooling and re-spooling repeatedly. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM Easy to install. Not Recommended for direct burial. Core-bonded Polyurethane jacket providing simple installation. |
Construction
| Fiber Color Code | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown |
|---|---|
| Cable Core Water Tight | Yes |
| Cable Core Water Blocking | Waterblocking Aramid Yarns |
| Bulk Cable Weight | 31 kg/km |
Fiber Cable Construction
| Fiber Type | OS2 |
|---|---|
| Fiber Grade acc. ITU-T | G.657A2 |
| Fiber Count | 4 |
Buffer Specification
| Fiber Type | OS2 |
|---|---|
| Buffer Construction | Tight |
| Buffer Material | Nylon |
| Buffer Diameter | 0.9 mm |
Physical Specifications
| Type of Armor | Non-Armored |
|---|
Jacket Specifications
| Number of Jackets | Single Jacket |
|---|
Outer Jacket Specifications
Outer Jacket
| Material | PUR - Polyurethane |
|---|---|
| Color | Black |
| Nominal Diameter | 5.8 mm |
| Ripcord | Yes |
Optical Characteristics
| Maximum Attenuation at 1310 nm | 0.40 dB/km |
|---|---|
| Maximum Attenuation at 1550 nm | 0.30 dB/km |
| Maximum Attenuation at 1625 nm | 0.30 dB/km |
Mechanical Characteristics
Mechanical Tests
| Description | Tested Standard | Requirement/Value | According to Family Specification |
|---|---|---|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 46.4 mm | |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 23.2 mm | |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 1650 N (371 lbf) | |
| Cable Max. Tensile Strength Operation (Long Term) | 550 N (124 lbf) | ||
| Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 5 kN/m | IEC 60794-2-20 |
| Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 3 kN/m | IEC 60794-2-20 |
Temperature Range
| Operating Temperature Range | -70 °C to +85 °C |
|---|---|
| Installation Temperature Range | -5 °C to +50 °C |
| Storage Temperature Range | -70 °C to +85 °C |
Product Material
| UL Rating/Flame Test | Non-UL Rated |
|---|
Standards
| IEC Flammability | IEC 60332-1-2 |
|---|---|
| REACH | Compliant |
| ISO/IEC Compliance | IEC 60794, ISO/IEC 11801-1 |
| UV/ Sunlight Protection | Yes |
History
| Update and Revision | Revision Number: 0.54 Revision Date: 09-17-2024 |
|---|