Belden Store
GMSN824

Product Number: GMSN824

Outdoor OFC CLT (jelly filled): GLASS YARNS + PUR with 1 Tube of Ø3.3mm 24f SM OS2 G.652.D & G.657.A1.

Outdoor (PUR jacket) optical fiber Central Loose Tube (jelly filled tube) cable with glass yarns as strength member and polyurethane outer jacket. Existing out of 1 Tube with a diameter of 3.3mm with 24 fibers SM OS2 G.652.D & G.657.A1.

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

GMSN824 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthEANOrder
GMSN824.002100BlackReel2,100 m8719605076595Order online

Specifications

Product Overview

Suitable ApplicationsFor outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor and indoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and/or tubes.

Fiber Specifications

Fiber TypeOS2
Fiber Grade Acc to ITU-TG.652D & G.657A1
Fiber Count24
Fiber Color CodingTIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua. With Ringmark: BL, OR, GR, BR, GY, WT, RD, BK, YL, VT, PK, AQ

Cable Construction

Number of Active Subunits1
Fibers Per Subunit24
Subunit WaterblockingGel Filled
Subunit Diameter3.3 mm
Subunit ColorTIA coding (Gxxxxxx.T): Natural
Cable Core Water BlockingWaterblocking Glass Yarns + Tape

Outer Jacket Specifications

Jacket MaterialPUR - Polyurethane
Nom. Diameter6.3 mm (0.25 in)

Optical Characteristics

WavelengthMax. Attenuation
1310 nm0.39 dB/km
1550 nm0.24 dB/km
1625 nm0.29 dB/km

Mechanical Characteristics

Bulk Cable Weight40 kg/km (27 lbs/1000ft)

Mechanical Tests

DescriptionTested StandardRequirement/ValueAccording to Family Specification
Cable Min. Bend Radius Installation (Short Term)IEC 60794-1-21-E694.5 mmIEC 60794-2-20
Cable Min. Bend Radius Operation (Long Term)IEC 60794-1-21-E1163 mmIEC 60794-2-20
Cable Max. Tensile Strength Installation (Short Term)IEC 60794-1-21-E11500 N (340 lbf)IEC 60794-2-20
Cable Max. Tensile Strength Operation (Long Term)IEC 60794-1-21-E1500 N (110 lbf)IEC 60794-2-20
Cable Max. Crush Resistance Installation (Short Term)IEC 60794-1-21-E315 kN/mIEC 60794-2-20
Cable Max. Crush Resistance Operation (Long Term)IEC 60794-1-21-E37.5 kN/mIEC 60794-2-20

Temperature Range

Installation Temperature Range-5 °C to +50 °C
Operating Temperature Range-30 °C to +70 °C
Storage Temperature Range-30 °C to +70 °C

Standards and Compliance

Environmental SuitabilityIndoor/Outdoor
ISO/IEC ComplianceIEC 60794 ISO/IEC 11801-1