Outdoor OFC CLT (jelly filled): GLASS YARNS + PUR with 1 Tube of Ø3.3mm 12f SM OS2 G.652.D & G.657.A1.
Outdoor (PUR jacket) optical fiber Central Loose Tube (jelly filled tube) cable with glass yarns as strength member and polyurethane outer jacket. Existing out of 1 Tube with a diameter of 3.3mm with 12 fibers SM OS2 G.652.D & G.657.A1.
- Availability
- Global
- Status
- Active
- Orderable items
- 2
Part numbers
GMSN812 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Putup Type | Length | Order |
|---|---|---|---|---|
| GMSN812.002100 | Black | Reel | 2,100 m | Order online |
| GMSN812.T02100 | Black | Reel | 2,100 m | Order online |
Specifications
Product Overview
| Suitable Applications | For outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor and indoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and/or tubes. |
|---|
Fiber Specifications
| Fiber Type | OS2 |
|---|---|
| Fiber Grade Acc to ITU-T | G.652D & G.657A1 |
| Fiber Count | 12 |
| Fiber Color Coding | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua |
Cable Construction
| Number of Active Subunits | 1 |
|---|---|
| Fibers Per Subunit | 12 |
| Subunit Waterblocking | Gel Filled |
| Subunit Diameter | 3.3 mm |
| Subunit Color | TIA coding (Gxxxxxx.T): Natural |
| Cable Core Water Blocking | Waterblocking Glass Yarns + Tape |
Outer Jacket Specifications
| Jacket Material | PUR - Polyurethane |
|---|---|
| Nom. Diameter | 6.3 mm (0.25 in) |
Optical Characteristics
| Wavelength | Max. Attenuation |
|---|---|
| 1310 nm | 0.39 dB/km |
| 1550 nm | 0.24 dB/km |
| 1625 nm | 0.29 dB/km |
Mechanical Characteristics
| Bulk Cable Weight | 40 kg/km (27 lbs/1000ft) |
|---|
Mechanical Tests
| Description | Tested Standard | Requirement/Value | According to Family Specification |
|---|---|---|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 94.5 mm | IEC 60794-2-20 |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 63 mm | IEC 60794-2-20 |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 1500 N (340 lbf) | IEC 60794-2-20 |
| Cable Max. Tensile Strength Operation (Long Term) | IEC 60794-1-21-E1 | 500 N (110 lbf) | IEC 60794-2-20 |
| Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 15 kN/m | IEC 60794-2-20 |
| Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 7.5 kN/m | IEC 60794-2-20 |
Temperature Range
| Installation Temperature Range | -5 °C to +50 °C |
|---|---|
| Operating Temperature Range | -30 °C to +70 °C |
| Storage Temperature Range | -30 °C to +70 °C |
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor |
|---|---|
| ISO/IEC Compliance | IEC 60794 ISO/IEC 11801-1 |
History
| Update and Revision | Revision Number: 0.253 Revision Date: 09-26-2025 |
|---|