Outdoor OFC CLT (jelly filled): GLASS YARNS + PUR with 1 Tube of Ø3.3mm 4f SM OS2 G.652.D & G.657.A1.
Outdoor (PUR jacket) optical fiber Central Loose Tube (jelly filled tube) cable with glass yarns as strength member and polyurethane outer jacket. Existing out of 1 Tube with a diameter of 3.3mm with 4 fibers SM OS2 G.652.D & G.657.A1.
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Environmental Space | Indoor/Outdoor |
|---|---|
| Suitable Applications | For outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor and indoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and/or tubes. |
Construction
| Fiber Color Code | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown |
|---|---|
| Cable Core Water Tight | Yes |
| Cable Core Water Blocking | Waterblocking Glass Yarns + Tape |
| Bulk Cable Weight | 40 kg/km |
Fiber Cable Construction
| Fiber Type | OS2 |
|---|---|
| Fiber Grade acc. ITU-T | G.652D & G.657A1 |
| Fiber Count | 4 |
| Subunit Color | TIA coding (Gxxxxxx.T): Natural |
SubUnit Specifications
| Number of Active Subunits | 1 |
|---|---|
| Number of Subunit Positions | 1 |
| Fibers Per Subunit | 4 |
Physical Specifications
| Type of Armor | Non-Armored |
|---|
Jacket Specifications
| Number of Jackets | Single Jacket |
|---|
Outer Jacket Specifications
Outer Jacket
| Material | PUR - Polyurethane |
|---|---|
| Nominal Diameter | 6.3 mm |
| Ripcord | No |
Optical Characteristics
| Maximum Attenuation at 1310 nm | 0.39 dB/km |
|---|---|
| Maximum Attenuation at 1550 nm | 0.24 dB/km |
| Maximum Attenuation at 1625 nm | 0.29 dB/km |
Mechanical Characteristics
Mechanical Tests
| Description | Tested Standard | Requirement/Value | According to Family Specification |
|---|---|---|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 94.5 mm | IEC 60794-2-20 |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 63 mm | IEC 60794-2-20 |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 1500 N (337 lbf) | IEC 60794-2-20 |
| Cable Max. Tensile Strength Operation (Long Term) | IEC 60794-1-21-E1 | 500 N (112 lbf) | IEC 60794-2-20 |
| Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 15 kN/m | IEC 60794-2-20 |
| Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 7.5 kN/m | IEC 60794-2-20 |
Temperature Range
| Operating Temperature Range | -30 °C to +70 °C |
|---|---|
| Installation Temperature Range | -5 °C to +50 °C |
| Storage Temperature Range | -30 °C to +70 °C |
Product Material
| UL Rating/Flame Test | Non-UL Rated |
|---|
Standards
| REACH | Compliant |
|---|---|
| ISO/IEC Compliance | IEC 60794, ISO/IEC 11801-1 |
| UV/ Sunlight Protection | Yes |
History
| Update and Revision | Revision Number: 0.73 Revision Date: 09-17-2024 |
|---|