Outdoor Tactical tight buffered distribution cable PUR jacket 6f MM OM1.
Outdoor Tactical tight buffered optical fiber distribution cable with Polyurethane (PUR) outer jacket. 6 fibers MM OM1.
- Availability
- Global
- Status
- Active
- Orderable items
- 2
Part numbers
GMMT106 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Putup Type | Length | EAN | Order |
|---|---|---|---|---|---|
| GMMT106.012100 | Black | Reel | 2,100 m | 8719605076267 | Order online |
| GMMT106.002100 | Orange | Reel | 2,100 m | 8719605076250 | Order online |
Specifications
Product Overview
| Suitable Applications | For outdoor and indoor use. These metal-free mobile cables have been designed for de-spooling and re-spooling repeatedly. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM Easy to install. Not Recommended for direct burial. |
|---|
Fiber Specifications
| Fiber Type | OM1 |
|---|---|
| Fiber Buffer Material | Nylon |
| Fiber Buffer Construction | Tight |
| Fiber Buffer Diameter | 0.9 mm |
| Fiber Count | 6 |
| Fiber Color Coding | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White |
Cable Construction
| Cable Core Water Blocking | Waterblocking Glass Yarns |
|---|
Outer Jacket Specifications
| Jacket Material | PUR - Polyurethane |
|---|---|
| Nom. Diameter | 6.3 mm (0.25 in) |
Optical Characteristics
| Wavelength | Max. Attenuation |
|---|---|
| 850 nm | 3.4 dB/km |
| 1300 nm | 0.9 dB/km |
Mechanical Characteristics
| Bulk Cable Weight | 38 kg/km (26 lbs/1000ft) |
|---|
Mechanical Tests
| Description | Tested Standard | Requirement/Value | According to Family Specification |
|---|---|---|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 50.4 mm | |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 25.2 mm | |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 400 N (90 lbf) | |
| Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 5 kN/m | IEC 60794-2-20 |
| Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 3 kN/m | IEC 60794-2-20 |
Temperature Range
| Installation Temperature Range | -15 °C to +50 °C |
|---|---|
| Operating Temperature Range | -55 °C to +85 °C |
| Storage Temperature Range | -70 °C to +85 °C |
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor |
|---|---|
| ISO/IEC Compliance | IEC 60794 ISO/IEC 11801-1 |
History
| Update and Revision | Revision Number: 0.203 Revision Date: 09-26-2025 |
|---|