Outdoor Tactical tight buffered breakout cable PUR jacket 2f MM OM4.
Outdoor Tactical tight buffered breakout cable with Polyurethane (PUR) outer jacket. 2 fibers MM OM4.
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Environmental Space | Indoor/Outdoor |
|---|---|
| Suitable Applications | For outdoor and indoor use. These metal-free mobile cables have been designed for de-spooling and re-spooling repeatedly. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM Easy to install. Not Recommended for direct burial. |
Construction
| Fiber Color Code | TIA coding (Gxxxxxx.T): Blue, Orange |
|---|---|
| Cable Core Water Tight | Yes |
| Cable Core Water Blocking | Waterblocking Aramid Yarns + Tape |
| Bulk Cable Weight | 38 kg/km |
Fiber Cable Construction
| Fiber Type | OM4 |
|---|---|
| Fiber Count | 2 |
Buffer Specification
| Fiber Type | OM4 |
|---|---|
| Buffer Construction | Tight |
| Buffer Material | Nylon |
| Buffer Diameter | 0.9 mm |
Physical Specifications
| Type of Armor | Non-Armored |
|---|
Jacket Specifications
| Number of Jackets | Single Jacket |
|---|
Outer Jacket Specifications
Outer Jacket
| Material | PUR - Polyurethane |
|---|---|
| Nominal Diameter | 7.8 mm |
| Ripcord | Yes |
Optical Characteristics
| Maximum Attenuation at 1300 nm | 0.9 dB/km |
|---|---|
| Maximum Attenuation at 850 nm | 2.9 dB/km |
Mechanical Characteristics
Mechanical Tests
| Description | Tested Standard | Requirement/Value | According to Family Specification |
|---|---|---|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 144 mm | IEC 60794-2-20 |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 72mm | IEC 60794-2-20 |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 400 N (90 lbf) | |
| Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | 5 kN/m | IEC 60794-2-20 |
| Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | 3 kN/m | IEC 60794-2-20 |
Temperature Range
| Operating Temperature Range | -30 °C to +70 °C |
|---|---|
| Installation Temperature Range | -5 °C to +50 °C |
| Storage Temperature Range | -30 °C to +70 °C |
Product Material
| UL Rating/Flame Test | Non-UL Rated |
|---|
Standards
| REACH | Compliant |
|---|---|
| ISO/IEC Compliance | IEC 60794, ISO/IEC 11801-1 |
| UV/ Sunlight Protection | Yes |
History
| Update and Revision | Revision Number: 0.144 Revision Date: 07-22-2026 |
|---|