Belden Store
Belden6000FH

Product Number: 6000FH

Security & Sound, 2 Conductor 12 AWG TC, CL2P

Security & Commercial Audio Cable, 2 Conductor 12 AWG stranded (19x25) tinned copper conductors with Flamarrest® insulation, Beldfoil® shield, plenum CL2P rating and Flamarrest® low smoke PVC jacket with ripcord.

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

6000FH is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCOrder
6000FH 8771000NaturalReel1,000 ft612825166092Order online

Specifications

Product Overview

Suitable ApplicationsCommercial Audio Systems, Intercom/PA Systems, Sound/Audio Systems

Construction Details

Overall Cable Diameter (Nominal)0.260 in

Conductor

ElementPair(s)
No. of Elements1
Size12 AWG
Stranding19x25
MaterialTC - Tinned Copper

Insulation

ElementPair(s)
MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.010 in (0.25 mm)
Nom. Insulation Diameter0.111 in (2.82 mm)
Color CodeBlack & White

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type20 AWG (Solid) TC

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.015 in (0.38 mm)
Nom. Diameter0.260 in
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR8.2 Ohm/1000ft (27 Ohm/km)

Electricals

Nom. Conductor DCR1.6 Ohm/1000ft
Nom. Capacitance Cond-to-Cond97 pF/ft (320 pF/m)
Nom. Capacitance Cond-to-Other (Conds + Shield)174.6 pF/ft (572.8 pF/m)
Nom. Inductance0.140 μH/ft (0.459 μH/m)
Max. Current12 Amps per Conductor at 25oC

Voltage

UL Voltage Rating300 V

Mechanical Characteristics

Max. Pull Tension164 lbs (74.4 kg)
Bulk Cable Weight57 lbs/1000ft

Temperature

UL Temperature75°C
Operating-20°C To +75°C

Bend Radius

Stationary Min.2.6 in (66 mm)
Installation Min.2.6 in

Standards and Compliance

Environmental SuitabilityIndoor - Plenum, Indoor
Flammability / Reaction to FireNFPA 262 (UL 910)
NEC / UL ComplianceArticle 725, CL2P
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Non-Plenum Number5000FH