Belden Store
1347A

Product Number: 1347A

Composite Data, Audio, Video, Security and Control

Composites, 2 Coax 20 AWG BC, GIFPE insulation, TC braid 95% coverage, overall foil tape and 4 PR 22 AWG TC, PP insulation, bonded foil tape plus drain wire, overall CMR rating and PVC jacket.

Availability
Global
Status
Active
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

1347A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCFootnoteOrder
1347A B59500Black, MatteReel500 ft612825112358COrder online
1347A B591000Black, MatteReel1,000 ft612825112341COrder online

Specifications

Product Overview

Suitable ApplicationsElectronic News Gathering (ENG), Electronic Field Production (EFP), Analog Audio + Digital Video Composite Applications, 2V + 4A

Construction Details

RG Type59
Overall Cable Diameter (Nominal)0.640 in

Conductor

ElementNo. of ElementsSizeStrandingNom. DiameterMaterial
Coax(es)220 AWGSolid0.034 inBC - Bare Copper
Pair(s)422 AWG7x300.0285 inTC - Tinned Copper

Insulation

ElementMaterialNom. Insulation DiameterColor CodeNotes
Coax(es)PE - Polyethylene (Foam)0.145 in (3.68 mm)White and Numbered
Pair(s)PP - Polypropylene0.046 in (1.2 mm)Black and Red and Numbered
Brown, Red, Orange, Yellowcolors mentioned here is for inner Jacket

Inner Shield

ElementShield TypeMaterialCoverageDrainwire Type
Each PairTapeTri-Laminate (Alum+Poly+Alum)100%22 AWG (7x30) TC
Coax(es)BraidTinned Copper (TC)93%
TapeTapeTri-Laminate (Alum+Poly+PVC)100%22 AWG (7x30) TC

Inner Jacket

ElementCoax(es)
MaterialPVC - Polyvinyl Chloride
Nom. Diameter0.233 in (5.92 mm)

Outer Shield

Outer Shield TypeMaterialMaterial Trade NameCoverage
TapeNo ShieldDuofoil®100%
BraidTinned Copper (TC)95%
TapeBi-Laminate (Alum+Poly)Beldfoil®100%
No Shield

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Diameter0.640 in

Electrical Characteristics

Return Loss

FrequencyMin. Return Loss
5-850 MHz20 dB
850-4500 MHz15 dB

Attenuation

FrequencyNom. Attenuation
1 MHz0.3 dB/100ft
3.6 MHz0.6 dB/100ft
5 MHz0.63 dB/100ft
7 MHz0.74 dB/100ft
10 MHz0.9 dB/100ft
67.5 MHz2.05 dB/100ft
71.5 MHz2.1 dB/100ft
88.5 MHz2.2 dB/100ft
100 MHz2.3 dB/100ft
135 MHz2.7 dB/100ft
143 MHz2.8 dB/100ft
180 MHz3.1 dB/100ft
270 MHz3.8 dB/100ft
360 MHz4.4 dB/100ft
540 MHz5.5 dB/100ft
720 MHz6.4 dB/100ft
750 MHz6.5 dB/100ft
1000 MHz7.6 dB/100ft
1500 MHz9.3 dB/100ft
2000 MHz10.9 dB/100ft
2250 MHz11.6 dB/100ft
3000 MHz13.4 dB/100ft
4500 MHz16.4 dB/100ft

Electricals

ElementNom. Conductor DCRNom. Inner Shield DCRNom. Outer Shield DCRNom. Characteristic ImpedanceNom. Velocity of Prop.Max. Current
Coax(es)11.3 Ohm/1000ft13.93 Ohm/1000ft (45.70 Ohm/km)75 Ohm82%8 Amps per Conductor at 30oC
Pair(s)18.2 Ohm/1000ft (59.7 Ohm/km)14.3 Ohm/1000ft (46.9 Ohm/km)14.3 Ohm/1000ft (46.9 Ohm/km)45 Ohm66%1.96 Amps per Conductor at 30oC

Voltage

UL Voltage Rating300 V

Mechanical Characteristics

Max. Pull Tension182.78 lbs (82.908 kg)
Bulk Cable Weight190 lbs/1000ft

Temperature

UL Temperature60°C
Operating-20°C to +60°C

Bend Radius

Stationary Min.6.40 in (163 mm)
Installation Min.6.40 in

Standards and Compliance

Environmental SuitabilityIndoor (Not Riser or Plenum), Indoor
Flammability / Reaction to FireUL1666 Riser, FT4, IEEE 1202 FT4
CPR ComplianceCPR Euroclass: Eca
NEC / UL ComplianceArticle 800, CMR
CEC / C(UL) ComplianceCMG.
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.466 Revision Date: 09-07-2025
FootnoteC - CRATE REEL PUT-UP.

Resources