Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden SPE403 0105000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: Noisy environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc.
- Conductor Size: 24 AWG
- Conductor Stranding: Stranded
- Conductor Material: TC - Tinned Copper
- Conductor No. of Pairs: 1
- Insulation Material: PE - Polyethylene
- Insulation Nom. Insulation Diameter: 0.075 in (1.9 mm)
- Insulation Color Code: Natural & Natural/Blue
Belden SPE403 0105000 is an orderable item number in the Belden SPE403 family (Cable › Ethernet Cable › Industrial Ethernet Cable). DataTuff Industrial Single Pair Ethernet 40m 1Gbps 100 Ohm 24AWG (Stranded) Tinned Copper, PE Insulation, Overall Beldfoil®+Tinned Copper Braid(80%) Shield, LSPUR Outer Jacket Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.40 Revision Date: 02-20-2026 |
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. |
Product Overview
| Suitable Applications | Noisy environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. |
Construction Details
| Conductor — Size | 24 AWG |
| Conductor — Material | TC - Tinned Copper |
| Conductor — Stranding | Stranded |
| Insulation — Material | PE - Polyethylene |
| Insulation — Color Code | Natural & Natural/Blue |
| Outer Jacket — Material | PUR - Polyurethane |
| Conductor — No. Of Pairs | 1 |
| Outer Jacket — Nom. Diameter | 0.217 in (5.51 mm) |
| Outer Shield Row 1 — Coverage | 100% |
| Outer Shield Row 1 — Material | Bi-Laminate (Alum+Poly) |
| Outer Shield Row 2 — Coverage | 80% |
| Outer Shield Row 2 — Material | Tinned Copper (TC) |
| Outer Shield Row 1 — Shield Type | Tape |
| Outer Shield Row 2 — Shield Type | Braid |
| Insulation — Nom. Insulation Diameter | 0.075 in (1.9 mm) |
Standards And Compliance
| AWM Compliance | AWM 20549, AWM I A/B |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| IEEE Compliance | IEEE 802.3bp |
| ISO/IEC Compliance | IEC 61156-12 |
| Environmental Suitability | Indoor, Outdoor, UV Resistance, Oil Resistance |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 |
| European Halogen Free Standards | IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
| Flammability / Reaction To Fire | FT2, IEC 60332-1-2 |
Electrical Characteristics
| Delay — Frequency | 100 MHz |
| Delay — Max. Delay | 538 ns/100m |
| Delay — Max. Delay Skew | 25 ns/100m |
| Voltage — Voltage Rating | 300 V (IEC 61156-12) |
| Voltage — UL Voltage Rating | 300 V (UL AWM 20549) |
| Electricals — Max. Conductor DCR | 94.2 Ohm/km (28.7 Ohm/1000ft) |
| High Frequency Row 1 — Min. TCL [DB] | 40 |
| High Frequency Row 2 — Min. TCL [DB] | 40 |
| High Frequency Row 3 — Min. TCL [DB] | 36.5 |
| High Frequency Row 4 — Min. TCL [DB] | 35.0 |
| High Frequency Row 5 — Min. TCL [DB] | 31.9 |
| High Frequency Row 6 — Min. TCL [DB] | 30.5 |
| High Frequency Row 7 — Min. TCL [DB] | 29 |
| High Frequency Row 8 — Min. TCL [DB] | 27.8 |
| High Frequency Row 9 — Min. TCL [DB] | 23.3 |
| High Frequency Row 10 — Min. TCL [DB] | 20 |
| High Frequency Row 11 — Min. TCL [DB] | 15.5 |
| High Frequency Row 12 — Min. TCL [DB] | 14 |
| High Frequency Row 13 — Min. TCL [DB] | 12.8 |
| High Frequency Row 14 — Min. TCL [DB] | 11.8 |
| High Frequency Row 15 — Min. TCL [DB] | 11 |
| High Frequency Row 16 — Min. TCL [DB] | 10.2 |
| High Frequency Row 17 — Min. TCL [DB] | 9.5 |
| High Frequency Row 18 — Min. TCL [DB] | 8.9 |
| High Frequency Row 19 — Min. TCL [DB] | 8.3 |
| High Frequency Row 1 — Frequency [MHz] | 1 |
| High Frequency Row 2 — Frequency [MHz] | 4 |
| High Frequency Row 3 — Frequency [MHz] | 8 |
| High Frequency Row 4 — Frequency [MHz] | 10 |
| High Frequency Row 5 — Frequency [MHz] | 16 |
| High Frequency Row 6 — Frequency [MHz] | 20 |
| High Frequency Row 7 — Frequency [MHz] | 25 |
| High Frequency Row 8 — Frequency [MHz] | 30 |
| High Frequency Row 9 — Frequency [MHz] | 60 |
| High Frequency Row 1 — Min. ELTCTL [DB] | 40 |
| High Frequency Row 10 — Frequency [MHz] | 100 |
| High Frequency Row 11 — Frequency [MHz] | 200 |
| High Frequency Row 12 — Frequency [MHz] | 250 |
| High Frequency Row 13 — Frequency [MHz] | 300 |
| High Frequency Row 14 — Frequency [MHz] | 350 |
| High Frequency Row 15 — Frequency [MHz] | 400 |
| High Frequency Row 16 — Frequency [MHz] | 450 |
| High Frequency Row 17 — Frequency [MHz] | 500 |
| High Frequency Row 18 — Frequency [MHz] | 550 |
| High Frequency Row 19 — Frequency [MHz] | 600 |
| High Frequency Row 2 — Min. ELTCTL [DB] | 28 |
| High Frequency Row 3 — Min. ELTCTL [DB] | 21.9 |
| High Frequency Row 4 — Min. ELTCTL [DB] | 20.0 |
| High Frequency Row 5 — Min. ELTCTL [DB] | 15.9 |
| High Frequency Row 6 — Min. ELTCTL [DB] | 14 |
| High Frequency Row 7 — Min. ELTCTL [DB] | 12 |
| High Frequency Row 8 — Min. ELTCTL [DB] | 10.5 |
| High Frequency Row 9 — Min. ELTCTL [DB] | 5 |
| Electricals — Max. Capacitance Unbalance | 1,600 pF/km |
| High Frequency Row 10 — Min. ELTCTL [DB] | 5 |
| High Frequency Row 11 — Min. ELTCTL [DB] | 5 |
| High Frequency Row 12 — Min. ELTCTL [DB] | 5 |
| High Frequency Row 13 — Min. ELTCTL [DB] | 5 |
| High Frequency Row 14 — Min. ELTCTL [DB] | 5 |
| High Frequency Row 15 — Min. ELTCTL [DB] | 5 |
| High Frequency Row 16 — Min. ELTCTL [DB] | 5 |
| High Frequency Row 17 — Min. ELTCTL [DB] | 5 |
| High Frequency Row 18 — Min. ELTCTL [DB] | 5 |
| High Frequency Row 19 — Min. ELTCTL [DB] | 5 |
| High Frequency Row 1 — Min. RL (Return Loss) [DB] | 20 |
| High Frequency Row 2 — Min. RL (Return Loss) [DB] | 23 |
| High Frequency Row 3 — Min. RL (Return Loss) [DB] | 24.5 |
| High Frequency Row 4 — Min. RL (Return Loss) [DB] | 25 |
| High Frequency Row 5 — Min. RL (Return Loss) [DB] | 25 |
| High Frequency Row 6 — Min. RL (Return Loss) [DB] | 25 |
| High Frequency Row 7 — Min. RL (Return Loss) [DB] | 24.2 |
| High Frequency Row 8 — Min. RL (Return Loss) [DB] | 23.5 |
| High Frequency Row 9 — Min. RL (Return Loss) [DB] | 20.9 |
| High Frequency Row 10 — Min. RL (Return Loss) [DB] | 19 |
| High Frequency Row 11 — Min. RL (Return Loss) [DB] | 16.4 |
| High Frequency Row 12 — Min. RL (Return Loss) [DB] | 15.6 |
| High Frequency Row 13 — Min. RL (Return Loss) [DB] | 14.9 |
| High Frequency Row 14 — Min. RL (Return Loss) [DB] | 14.3 |
| High Frequency Row 15 — Min. RL (Return Loss) [DB] | 13.8 |
| High Frequency Row 16 — Min. RL (Return Loss) [DB] | 13.4 |
| High Frequency Row 17 — Min. RL (Return Loss) [DB] | 13 |
| High Frequency Row 18 — Min. RL (Return Loss) [DB] | 12.6 |
| High Frequency Row 19 — Min. RL (Return Loss) [DB] | 12.3 |
| High Frequency Row 8 — Min. Coupling Attenuation [DB] | 84 |
| High Frequency Row 9 — Min. Coupling Attenuation [DB] | 85 |
| High Frequency Row 10 — Min. Coupling Attenuation [DB] | 85 |
| High Frequency Row 11 — Min. Coupling Attenuation [DB] | 79 |
| High Frequency Row 12 — Min. Coupling Attenuation [DB] | 77 |
| High Frequency Row 13 — Min. Coupling Attenuation [DB] | 75 |
| High Frequency Row 14 — Min. Coupling Attenuation [DB] | 74 |
| High Frequency Row 15 — Min. Coupling Attenuation [DB] | 73 |
| High Frequency Row 16 — Min. Coupling Attenuation [DB] | 72 |
| High Frequency Row 17 — Min. Coupling Attenuation [DB] | 71 |
| High Frequency Row 18 — Min. Coupling Attenuation [DB] | 70 |
| High Frequency Row 19 — Min. Coupling Attenuation [DB] | 69 |
| High Frequency Row 1 — Max. Insertion Loss (Attenuation) | 3.1 dB/100m |
| High Frequency Row 2 — Max. Insertion Loss (Attenuation) | 5.6 dB/100m |
| High Frequency Row 3 — Max. Insertion Loss (Attenuation) | 7.8 dB/100m |
| High Frequency Row 4 — Max. Insertion Loss (Attenuation) | 8.7 dB/100m |
| High Frequency Row 5 — Max. Insertion Loss (Attenuation) | 11 dB/100m |
| High Frequency Row 6 — Max. Insertion Loss (Attenuation) | 12.3 dB/100m |
| High Frequency Row 7 — Max. Insertion Loss (Attenuation) | 13.8 dB/100m |
| High Frequency Row 8 — Max. Insertion Loss (Attenuation) | 15.1 dB/100m |
| High Frequency Row 9 — Max. Insertion Loss (Attenuation) | 21.4 dB/100m |
| High Frequency Row 10 — Max. Insertion Loss (Attenuation) | 27.8 dB/100m |
| High Frequency Row 11 — Max. Insertion Loss (Attenuation) | 39.7 dB/100m |
| High Frequency Row 12 — Max. Insertion Loss (Attenuation) | 44.6 dB/100m |
| High Frequency Row 13 — Max. Insertion Loss (Attenuation) | 49.0 dB/100m |
| High Frequency Row 14 — Max. Insertion Loss (Attenuation) | 53.2 dB/100m |
| High Frequency Row 15 — Max. Insertion Loss (Attenuation) | 57.0 dB/100m |
| High Frequency Row 16 — Max. Insertion Loss (Attenuation) | 60.7 dB/100m |
| High Frequency Row 17 — Max. Insertion Loss (Attenuation) | 64.1 dB/100m |
| High Frequency Row 18 — Max. Insertion Loss (Attenuation) | 67.5 dB/100m |
| High Frequency Row 19 — Max. Insertion Loss (Attenuation) | 70.7 dB/100m |
| High Frequency Row 1 — Max. Surface Transfer Impedance [MOhm/m] | 50 |
| High Frequency Row 2 — Max. Surface Transfer Impedance [MOhm/m] | 76 |
| High Frequency Row 3 — Max. Surface Transfer Impedance [MOhm/m] | 93 |
| High Frequency Row 4 — Max. Surface Transfer Impedance [MOhm/m] | 100 |
| High Frequency Row 5 — Max. Surface Transfer Impedance [MOhm/m] | 135 |
| High Frequency Row 6 — Max. Surface Transfer Impedance [MOhm/m] | 155 |
| High Frequency Row 7 — Max. Surface Transfer Impedance [MOhm/m] | 178 |
| High Frequency Row 8 — Max. Surface Transfer Impedance [MOhm/m] | 200 |
Mechanical Characteristics
| Bulk Cable Weight | 11.5 lbs/1000ft |
| Temperature — Operating | -40°C To +80°C |
| Temperature — UL Temperature | 80°C |
| Bend Radius — Installation Min. | 2.2 in (56 mm) |